DEKEMA Overflow Valve BST-06H-2B2-A240-N-50
Type: Overflow Valve
Brand: DEKEMA
Model:BST-06H-2B2-A240-N-50
Type: Overflow Valve
Brand: DEKEMA
Type: Overflow Valve
Brand: DEKEMA
TOYOOKI Overflow Valve HRU3ー80G*K(D)ー06
DUPLOMATIC Overflow Valve MZD3-50
SMC Proportional Valve ITV2050-01T3N
SANWO Check Valve SC1200F 6-M5
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LNTECH Light Curtain SNA2040-W-F
Festo Air Cylinder ADVULQ-25-30-A-P-A
Honeywell Sensor 41SM1-T2
AirTAC Air Cylinder BSC63X1000
06/21/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
09/05/2020
In the current air compressor market, energy saving has become the mainstream word in the industry. Energy-saving air compressors are emerging one after another, and the air compressor frequency conversion control technology is becoming more and more mature.
07/13/2023
Air conditioning compressors are essential components of an air conditioning system, responsible for compressing refrigerant and circulating it through the system.
07/13/2020
Danfoss H series scroll compressor flexible sealing technology The scroll compressor is a positive displacement compressor, and the compression component is mainly composed of a movable scroll and a fixed scroll. The scroll compressor was first born in 1905 and was invented by the French engineer Leon Creux.
07/31/2020
The electrical control and air circulation of the computer room air conditioner are independent units. During maintenance and overhaul, the air conditioner does not need to be turned off, and the stable air flow and temperature gradient in the air conditioner room can also be ensured
06/25/2020
Many people say that buying an air conditioner means buying a compressor. This is true. Simply put, the quality and life of the compressor determine the attitude of most people to buy. So what are the common compressor brands in the market? What compressors are used in these brand air conditioners?
06/14/2020
Fault phenomenon: After a Mitsubishi SRC285cENF air conditioner is turned on, the indoor fan operates normally, and the indoor compressor does not rotate and cannot be cooled.
07/23/2020
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.
08/15/2020
In the process of maintenance of the refrigerator, if there is a fault in the system components from the compressor exhaust shut-off valve to the accumulator outlet valve
01/21/2022
This article introduces the compressor magnetic clutch components and their working principle, as well as several important parameters.