FORCE Piston Pump FASD-60-HP-L-CS
Type: Piston Pump
Brand: FORCE
There is no price at present, you can Request a Quote
Type: Piston Pump
Brand: FORCE
There is no price at present, you can Request a Quote
Type: Piston Pump
Brand: FORCE
There is no price at present, you can Request a Quote
NACHI Piston Pump 180N3-10 180N4-10
MOOG Piston Pump HPR18A1 RKP032KM28H1Z00
HPC Piston Pump PP22-A3-F-R-2A+P16-A3-S
NACHI Piston Pump PVS-0B-8N0-U-30-U61
NACHI Check Valve OC-G03-A3-J50
VOLVO Overflow Valve EC460
TAICIN Vane Pump VDV-1C-F20-D-35
HYDROMAX Gear Pump HGP-05A-F1.1L
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Rockwell Allen-Bradley AB VFD 20F14GC456JN0NNNNN
KORCHIP Capacitor 2.5V 5F
MEDER Relay CRR05-1AS
06/18/2020
The main reason for the slow heating of air conditioners There are several reasons for the slow heating of air conditioners: The dirt of the transpiration device and the condenser is too thick, which will cause air flow blockage, affect the heat declaration, and make the air conditioning heating a big discount. The filter is not cleaned for a long time<img src="{{media url="wysiwyg/The_main_reason_for_the_slow_heating_of_air_conditioners.jpg"}}" alt="" />
08/13/2020
1. Pressure gauge operation method:<br></br> Generally, in the refrigeration industry nowadays, a compound double meter is used to measure the pressure of the refrigeration system, charge refrigerant, and vacuum, etc. It is widely used.
07/19/2020
We know that the operation of the internal compression structure of the refrigeration compressor has a fixed direction. First of all, we need to make it clear: the occurrence of reverse rotation must be unfavorable for the refrigeration compressor.
10/02/2023
When it comes to choosing a clothes dryer, there are a lot of options to consider. One of the most important decisions you'll make is whether to go with a dryer with a heat pump or a condenser. Both options have their pros and cons, so it's essential to understand the key differences between the two.
06/29/2020
What are the causes, treatment and prevention methods of compressor liquid blow Liquid blow means that the refrigerant liquid or wet steam is sucked into the compressor by the compressor due to failure or insufficient absorption of heat, which is called liquid blow. First, the main reasons are as follows:
07/10/2023
Heat pumps are an efficient and effective way to heat and cool your home, but they can sometimes be loud and noisy. A noisy heat pump can be a nuisance, and in some cases, it can indicate a problem with the system.
03/01/2021
As an open-loop control system, stepping motor has essential connection with modern digital control technology. In the current domestic digital control system, stepping motor is widely used. With the emergence of all digital AC servo system, AC servo motor is more and more used in digital control system. In order to adapt to the development trend of digital control, stepping motor or full digital AC servo motor is mostly used as the executive motor in motion control system. Although they are similar in control mode (pulse train and direction signal), they are quite different in performance and application. This paper compares the performance of the two.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
02/27/2021
How to maintain the servo motor 1. Regularly check the encoder connection line of the servo motor and the power connector of the servo motor to confirm that the connection is firm;
08/26/2020
Screw compressors, also known as screw compressors, are divided into single screw compressors and twin screw compressors. The single screw compressor was developed by Sinn, France in the 1970s.