Hardware resolution: 16 bits
Conversion time: 150 μs/channel
Reference error (normal temperature): the voltage mode is 0.1%
The current mode is 0.1%
Reference error (full temperature range): voltage mode is 0.45%
The current mode is 0.2%
Linearity error (normal temperature): voltage mode is 0.07%
The current mode is 0.05%
Linearity error (full temperature range): voltage mode is 0.12%
The current mode is 0.23%
Support hot plug
Signal isolation design
Have diagnostic function
Module status LED display
Support interrupt function
Delta PLC Analog I/O Module AH08AD-5A
People who bought this item also viewed
Omron PLC P79C-ID16
Omron PLC NX-AD3603
Delta Servo Motor ECMA-E21820PS
Yaskawa Servo Drive SGD7S-R90A30A002
HENGSTLER Encoder RI58-O/2048AK.42TB
Beckhoff Module M2400-012
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder ACED125X300
TAIYO Capacitor L2K212BJ105KD-T
Dwyer Switch 1005E-A1-J
ABB Circuit Breaker 10138821
Recent related posts
-
08/09/2020
Rosemount 3144P temperature transmitter FF fieldbus manual!
power supply Rosemount temperature transmitter FOUNDAIION fieldbus uses standard fieldbus power supply. The operating voltage of the transmitter is 9 to 32Vdc with a maximum of 11 mA. The rated voltage at the transmitter end is 42.4V dc, Wiring diagram
-
06/14/2020
Honored for community contributions – Mitsubishi Heavy Industries Compressor International awarded 'Business of the Year'
The Pearland Chamber of Commerce, has honored Mitsubishi Heavy Industries Compressor International (MCO-I) with the Business of the Year award at their 2020 Annual Banquet.
-
08/20/2020
How to adjust the energy of the compressor of the screw chiller
The compressors used in screw chillers generally have brands such as Taiwan Hanbell and German Bitzer, which belong to the screw compressor series. An obvious feature of this type of compressor is that it can perform an energy adjustment action on it according to different
-
06/21/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
12/02/2021
Calibration of Rosemount Transmitter
When adjusting the transmitter, please turn off the protection setting, which is usually the red switch in front of the meter and its status may be ON or OFF.
-
09/21/2020
Working principle and usage method of motor bearing grease
Working principle and usage method of motor bearing grease The lubrication of the motor bearing relies on the lubricating oil that is precipitated when the three-dimensional fiber network structure in the grease is broken under the action of shear, forming a layer of lubricating film on the rotating elements of the bearing, the bearing seat and the bearing race for lubrication Effective.
-
07/12/2020
What semi-hermetic screw compressors are customers willing to pay for?
In the early years, many people felt that semi-hermetic screw compressors are expensive and have high technical threshold. Without semi-hermetic piston compressors, they are cheap and easy to use and maintain, so they are a bit daunted.
-
06/24/2020
Why is the air conditioner not cooling
1.Check whether the compressor is working normally. If the compressor is broken, the air conditioner cannot start normally and there will be no cooling effect. 2. There is not enough refrigerant in the air conditioner. At this time, you need to add Freon, and the time for adding Freon can be very long. 3. The air conditioner itself has quality problems and the electrical components have failed. In this case, you need to find a master to repair it.
-
08/16/2020
The difference between duct air conditioner and split air conditioner
1. What is split air conditioner Split type is the name to distinguish it from the window machine. The compressor, condenser, evaporator and other components of the window air conditioner are all connected together.
-
09/06/2022
What is Synchronous Reluctance Motor and How Does It Work
Synchronous Reluctance Motor (referred to as SynRM) is a new type of AC electric motor that forms a closed loop along the path of least magnetic reluctance