Recent related posts
-
07/27/2020
Selection and comparison of compressors
1. Piston compressor (the work of the piston compressor is the continuous change of the working volume formed by the cylinder, the valve and the reciprocating piston in the cylinder).
-
01/17/2024
Industrial Fans: Advantages, Functions and Differences from Ordinary Fans
Industrial fans are widely used in factory workshops, logistics warehouses, basketball stadiums, stations, dairy farms, etc.
-
03/10/2021
Servo driver related parameter setting method
Position feedforward gain: set the feedforward gain of the positioning loop. The larger the set value is, the smaller the position delay isand the larger the feedforward gain of the position loop is, the high-speed response of the control system will rise, but the position of the system is unstable and prone to oscillation. When high response characteristics are not required, this parameter is usually set to 0, indicating the range of 0 ~ 100%.
-
11/06/2022
What is an Electronic Expansion Valve?
The electronic expansion valve is a kind of the expansion valve. It uses the electrical signal generated by the adjusted parameters to control the voltage or current applied to the expansion valve, thereby achieving the purpose of adjusting the liquid supply.
-
07/27/2020
The use and maintenance operation of screw unit
Parallel unit: generally composed of the same type of compressor, but also can be composed of different types of compressors. It can be composed of the same type of compressor, or it can be composed of different types of compressors (such as piston machine + screw machine). As shown below:
-
08/15/2020
How to install large-scale cold storage refrigeration equipment
The cold storage is mainly used as a constant temperature storage air-conditioning equipment for food, dairy products, meat, aquatic products, etc. The cold storage is a kind of low-temperature cold storage and also a kind of refrigeration equipment.
-
07/18/2020
reasons why the constant temperature and humidity test chamber does not cool
1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil damage the suction valve plate when the gas is sucked into the cylinder of the compressor, and it is produced when the piston is compressed when the piston is close to the top dead center and is not quickly discharged during the exhaust process after entering the cylinder.
-
08/11/2020
The name of each part of the cold storage
Compressor: It acts to compress and drive the refrigerant in the refrigerant circuit. The compressor extracts the refrigerant from the low-pressure zone, compresses it, and sends it to the high-pressure zone for cooling and condensation.
-
10/16/2020
How to distinguish true and false Copeland compressors
Every year in the refrigeration peak season, there are always some non-original Copeland compressors from OEM or refurbished companies appearing on the market. Due to the current many models of Copeland compressors, the market is relatively chaotic, which will affect purchases.
-
06/20/2020
Common system failures of refrigeration equipment
Common system failures of refrigeration equipment 1. Liquid return: For refrigeration systems using expansion valves, liquid return is closely related to the selection and use of expansion valves. Expansion valve selection is too large, the superheat setting is too small, the installation method of the temperature sensor is incorrect, the insulation bandage is damaged, and the expansion valve failure may cause liquid return.<img src="{{media url="Common_system_failures_of_refrigeration_equipment2.png"}}" alt="" />