PROCESSOR MODULE 2SLOT MICREX-F
Fuji PLC PROCESSOR MODULE NC1P-S2
People who bought this item also viewed
Omron PLC CP1W-32ET
LG LS PLC XBC-DR60XS
Panasonic Servo Motor MDME402SCH
MitsubishiServo DriveMR-J3W-44B
Autonics Rotary Encoder E50S8-800-6-N-24
IXYS Rectifier Module VUB72-16NOXT
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TYCO Relay IHV350AANFA
SUNON Fan GB1206PHV1-AY
Recent related posts
-
07/20/2022
Common Faults and Solutions of Diaphragm Pump
During the operation of the diaphragm pump, there should be no abnormal sound, and all parts should be free of running, emitting, dripping, leakage and other phenomena.
-
07/13/2020
Danfoss medium temperature refrigeration compressor M series
liquid 1. Liquid back: When the refrigerant returned to the compressor is not a pure gas state, but contains liquid, the influence of the liquid refrigerant on the compressor is negative. If there is too much liquid, it may even cause liquid shock, even if there is no liquid shock, it will happen. Wet compression causes oil to run away.
-
06/14/2020
Commercial Refrigeration Compressor Market to Surge at 221.7 Million units by 2026; Introduction of Advanced Technologies to promote Growth, Says Fortune Business Insights™
Key Companies Covered in Commercial Refrigeration Compressor Market Research Report Are Carrier Corporation, Daikin Industries Ltd., Johnson Controls Pvt. Ltd., Mitsubishi Electric, Bitzer, Emerson Climate Technologies, Ingersoll Rand Inc., Rechi Precisio 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
07/19/2020
Advantages of adding economizer to screw chiller
The temperature control range of the standard screw chiller is 3~35℃, and the efficiency is significantly reduced when operating under lower temperature conditions. In order to meet the temperature requirements of more industries for chillers, make the single-stage screw compressor work according to the two-stage refrigeration cycle and achieve the effect of energy saving, an economizer can be added to the unit.
-
06/22/2020
Reasons for poor cooling of air conditioners
The temperature in summer is high, and many of the owners' friends need air conditioning to spend the hot summer in the room. However, some owners often have such problems when using air conditioning in summer, such as poor air conditioning cooling. So, what are the reasons for poor air conditioning and cooling? How to solve the poor air conditioning and cooling? One of the reasons for poor air-conditioning and cooling: Freon is not enough (commonly known as fluoride deficiency) <img src="{{media url="magefan_blog/Reasons_for_poor_cooling_of_air_conditioners.jpg"}}" alt="" />
-
06/21/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
01/11/2023
What is a Directional Control Valve?
Hydraulic valves are used to control the flow direction or adjust the flow and pressure of liquids (oil, water, or air) in hydraulic systems.
-
06/28/2020
Which air conditioners are used by Hitachi compressors
Hitachi compressor technology is mature, good quality, reliable performance, is the first compressor used by Gree, Midea, Chigo, Haier and other air-conditioning manufacturers. okmarts.com is an authorized dealer of Hitachi compressors, with complete specifications and sufficient supply, which can meet your purchasing needs at any time.
-
06/14/2020
Analysis on application of overload protector for refrigeration compressor
Refrigeration compressor is the main key component of air conditioner and refrigerator, which is called "heart". Since the 1980s, my country has successively introduced technology and equipment, and its production capacity has reached about 20 million uni 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ
-
07/28/2020
FAQs on refrigeration compressors, do you know these?
Impurities entering the friction surface of the moving parts in the compressor pump body will cause abnormal scratches and wear. Impurities entering the solenoid valve, expansion valve, control valve