VIGOR PLC VB1-14MT-D
People who bought this item also viewed
Omron PLC CP1W-DAB21V
Omron PLC CJ2M-CPU14
Yaskawa Servo Motor SGMAH-02AAAYU21
Fanuc Servo Drive A06B-6066-H004
HENGSTLER Encoder RI38-O/32EQ.11KB
Beckhoff Terminal Box Module IE2808
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve VPA544-03A
NACHI Vane Pump VDC-3A-1A3-20
SAJ VFD Frequency Converter 8000B-4T022G
Recent related posts
-
07/19/2022
What is Diaphragm Pumps
A diaphragm pump (also known as a Membrane pump) is a positive displacement pump that uses a combination of the reciprocating action of a rubber
-
08/09/2020
What are the differences between non-standard refrigerators and standard refrigerators
Non-standard refrigerator means that it is different from standard refrigerator. Let’s take a box-sealed refrigerator as an example. It is mainly composed of a compressor, an evaporator, a condenser,
-
07/29/2020
Analysis of the seven major causes of air-conditioning freezing, the idea should be correct, and the troubleshooting should be accurate and fast~
Small split air conditioners often have icing in the indoor unit evaporator in summer. Why does it freeze and how to eliminate it? Here are the following:
-
09/04/2020
Have you considered these four questions when using screw air compressors
When using a screw air compressor, have you considered these four issues: the speed of the screw air compressor, the working temperature of the screw air compressor, the lubrication method of the screw air compressor, and the use environment of the screw air compressor.
-
07/01/2020
Share the characteristics of ZR series Copeland compressors
Share the characteristics of ZR series Copeland compressors There are many types of compressors, and this is what everyone knows. One of them is the Copeland compressor. Due to the advancement of technology, the Copeland compressor has begun to have various series and styles. The function of each series and style is different. Copeland Compressor
-
06/14/2020
What is the effect of pressure and temperature on the refrigeration system
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/28/2020
Compressor-Hitachi Inverter Compressor
From the current development trend of refrigeration compressors, in order to make it compact, efficient, energy-saving and low vibration and low noise, it has become the goal that air-conditioning compressors continue to pursue in manufacturing technology. Its role is mainly manifested in the following points: compressor
-
06/14/2020
Common failures of half-sealed piston compressors
Common failures of half-sealed piston compressors 1. The compressor cannot start normally 1. First check whether the power supply voltage is too low or the motor line is poorly connected. If the grid voltage is too low, start again after the grid volt 器2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
09/09/2022
Types of DC Motors
According to the reversible principle of DC motors, DC motors are divided into DC motors and DC generators.