Maximum output power of single channel up to 180W, output voltage 150V and output current 1.2A (IT6874A, IT6874B)
Dual range output capability
High output voltage and current resolution
1mV/0.1mA (IT6861A, IT6861B, IT6862A, IT6862B, IT6863A, IT6863B, IT6872A, IT6872B, IT6873A, IT6873B)
1mV (<100V), 10mV (>=100V)/0.1mA (IT6874A, IT6874B)
High output voltage and current accuracy
< = 0.04percent + 8mV/< = 0.1percent + 5mA (IT6861A, IT6861B, IT6862A, IT6862B, IT6863A, IT6863B, IT6872A, IT6872B, IT6873A, IT6873B)
< = 0.05percent + 20mV/< = 0.1percent + 5mA (IT6874A, IT6874B)
High voltage and current readback resolution
1mV/0.1mA (IT6861A, IT6861B, IT6862A, IT6862B, IT6863A, IT6863B, IT6872A, IT6872B, IT6873A, IT6873B)
1mV (<100V), 10mV (>=100V)/0.1mA (IT6874A, IT6874B)
High output voltage and current readback accuracy
< = 0.04percent + 8mV/< = 0.1percent + 5mA (IT6861A, IT6861B, IT6862A, IT6862B, IT6863A, IT6863B, IT6872A, IT6872B, IT6873A, IT6873B)
< = 0.05percent + 20mV/< = 0.1percent + 5mA (IT6874A, IT6874B)
Low ripples/low noise (20Hz-20MHz)
< = 2mVp-p/0.5mVrms (20V/5A range) and < = 3mVp-p/1mVrms (8V/9A range) (IT6861A, IT6861B)
< = 3mVp-p/0.5mVrms (32V/3A range) and < = 4mVp-p/1mVrms (12V/6A range) (IT6862A, IT6862B)
< = 3mVp-p/1mVrms (IT6863A, IT6863B, IT6872A, IT6872B, IT6873A, IT6873B)
< = 5mVp-p/1.5mVrms (IT6874A, IT6874B)
Dynamic recovery time in recovery of 75mV
<0.00005s (IT6861A, IT6861B, IT6862A, IT6862B, IT6863A, IT6863B, IT6872A, IT6872B, IT6873A, IT6873B)
<0.00001s (IT6874A, IT6874B)
Convenient data entry via knob or numerical key pad
Output programmed voltage and current
Intelligent fan control, energy conservation and noise reduction
List mode: Capable output wave based on edit voltage/current with time variations
Adjustable output timer function: 1s - 9999.9s
Remote sense: The remote sense interface to compensate line voltage, increase output accuracy
Protection functions on OVP, OCP and OTP
Versatile interface
RS232 and USB are provided as standard
GPIB is provided as standard (IT6861B, IT6862B, IT6863B, IT6872B, IT6873B, IT6874B)
ITECH Power Supply IT6863B
People who bought this item also viewed
Delta Power Supply DPS-150AB-3 A
Yaskawa Servo Motor SGMJV-04ADAB1
Fanuc Servo Drive A06B-6134-H202#A
Danfoss Transmitter 060G1023
NMB-MAT Fan 4715KL-04W-B30
IXYS Rectifier Module VUO120-16NO2T
Pilz Relay 774736
HAZE Battery HZB12-15T
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Belimo Actuator LR230A
SKF Oil Seal 280X320X20 CRWA1 V(FKM)
TAKEX Sensor GT3N
OMRON Relay G3HD-202SN DC12-24V
Contrinex Sensor LLK-5050-003-503
Recent related posts
-
08/15/2020
What should I do if the refrigeration performance of industrial refrigerators declines
When many enterprise users use industrial refrigerators, due to the lack of knowledge about the use and maintenance of equipment, industrial refrigerators are prone to various failures
-
06/14/2020
Frozen meat thawed repeatedly 15 times Will it become zombie meat after being frozen for a long time Must be clear today
Frozen meat thawed repeatedly 15 times Will it become zombie meat after being frozen for a long time Must be clear today Now that the living conditions are good, the meat is bought in large chunks, frozen at home, and cut a little when you want to eat. 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ъ 識
-
07/07/2022
Installation and Adjustment of Proportional Valves in Your Car
The proportional valve is mounted between the brake line master cylinder and the rear wheels. It's designed to adjust the pressure between the front and rear brakes, depending on how hard you're stopping.
-
06/24/2020
What to do if the refrigerator does not cool in winter
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
-
06/23/2020
What to do if the refrigerator does not cool in winter
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
-
06/14/2020
Refrigerator industry ushered in major changes, compressor refrigeration or history
Refrigerator industry ushered in major changes, compressor refrigeration or history
-
09/23/2020
Automatic control scheme for multiple adsorption dryers and air compressors
With the development of modern industry and the improvement of automation level, various industries have higher and higher requirements for air supply, purification level, automatic control, and continuous and reliable air supply of air compressor stations.
-
08/19/2020
Causes and prevention of fire in FRP cooling tower
FRP polyurethane insulation pipes are only a small part of the application of FRP products. Nowadays, the consumption of FRP materials in China is very large each year. For example, the application of FRP cooling towers.
-
06/06/2023
How Do You Know If Your Refrigerator Compressor is Bad?
The compressor is the heart and core component of the refrigerator. If the compressor doesn't work, the entire refrigerator won't function.
-
06/14/2020
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal, whether the fuse has been blown due to starting overload