The precision LED digital display is intuitive and clear.
The 12cm intelligent temperature-controlled fan has excellent heat dissipation effect, effectively extending the life of the fan and reducing noise.
Using advanced technology, it effectively reduces the weight of the power supply and facilitates power movement.
Multiple protection features, adjustable overvoltage protection (OVP), current limit protection (OCP), over temperature protection (OTP), over power protection (OPP).
Plastic panel, beautiful, handle design, easy to carry.
Technical Parameters:
Input voltage: 220Vfloat10% @50Hzfloat5Hz
???????????????????????????110Vfloat10% @60Hz float 5Hz
Output voltage: DC 0-110V
Output current: DC 0-3A
Display accuracy: float 1% float 1 word, voltage resolution 0.1V, current resolution 0.1A)
Boot delay: 3-5S shutdown delay: 1-10S (depending on load)
Voltage stability: <=0.2%
Current stability: <=0.5%
Load stability: <=0.5%
Ripple and noise: <=1% (effective value)
Machine efficiency: >=86% (tested under full load)
Working environment: -10 - +40 Degree Celsius relative humidity 20% -90% (non-condensing)
Storage environment: -20 - +80 Degree Celsius relative humidity 20% -80% (non-condensing)
Withstand voltage test: input-output: 1.5KVAC/1 minute
????????????Input - Housing: 1.5KVAC / 1 minute
????????????Output - Housing: 500VAC / 1 minute grounding resistance: <20 miliiohm
LW Power Supply LW-12003KD
People who bought this item also viewed
MURR Power Supply 85004
Delta Power Supply DPS-600QB A
MURR Power Supply 85362
Panasonic Servo Motor MSMF5AZL1C1
Fanuc Servo Drive A06B-6142-H026#H580
Huba Control Transmitter 692.9300071A1
Omron PLC CJ1W-PDC15
Sanyo Denki Fan 9BD12FA6-1
Oriental Motor Electric Motor ASM911AA
Schneider Controller Module PC-A984-145
GS Battery N50L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
P+F Pepperl Fuchs Sensor NBB1,5-4M25-E2
Banner Sensor SMW915LVAGQD
Fuji Circuit Breaker EW50RAGU-3P050
TYCO Relay HF693
MINDMAN Air Cylinder MCQA-11-32-650
BRIDGE Welding Wire THS-310
Recent related posts
-
07/24/2023
An Introduction to Heat Pump Parts (with Heat Pump Parts Diagram)
Heat pumps are an energy-efficient alternative to traditional HVAC systems for heating and cooling your home. They work by transferring heat from one place to another, using a combination of several key components
-
09/07/2020
How to save energy in the dryer in the compressed air purification system
In many industrial occasions, compressed air systems have very high requirements for the water content of compressed air, such as: chemical, pharmaceutical, spraying, power electronics and other industries;
-
05/19/2023
Why is My Central AC Running but Not Blowing Air?
Air conditioners are used very frequently in summer, and the possibility of problems is very high. Air conditioner common faults are ·Blockage of the refrigeration system, the air filter, the air inlet and outlet, etc
-
02/15/2022
Factors Affecting Service Life of the Air Compressor Oil
Maintaining the air compressor oil is critical to the compressor’s performance.
-
07/18/2020
A coup to avoid the oil return problem of the refrigeration compressor of the piston chiller
Compressor: It is a complex machine running at high speed. Ensuring adequate lubrication of moving parts such as compressor crankshafts, bearings, connecting rods, pistons, etc. is the basic requirement for maintaining the normal operation of the machine. For this reason, compressor manufacturers require the use of specified grades of lubricating oil, and require regular inspection of the lubricating oil level and color
-
07/05/2022
8 Common Concerns about Magnet Pumps
Magnet pumps are very different from typical sealed pumps. Therefore, it is natural for people to have concerns. I narrowed the list to 8 questions that are commonly asked with regard to mag-drive pumps.
-
08/13/2020
How to use common refrigeration tools
1. Pressure gauge operation method:<br></br> Generally, in the refrigeration industry nowadays, a compound double meter is used to measure the pressure of the refrigeration system, charge refrigerant, and vacuum, etc. It is widely used.
-
07/13/2020
Danfoss expert analysis! Causes and troubleshooting of compressor start-up with liquid
Identify the authenticity of Danfoss compressors, solenoid valves, expansion valves, and filters Danfoss T2 valve true and false comparison:
-
08/19/2020
How much does it cost to build a cold storage
The cold chain has been naturally pushed to the forefront of the storm and has become a hot topic in the food logistics industry. The construction of a cold chain system is of great significance.
-
09/07/2020
How to choose the first flange sealing surface form of the pressure vessel using flange connection
The flange welded by the connecting pipe on the pressure vessel cylinder to the flange is the first flange connected to the pressure vessel flange, and the flange that is matched with it is not counted as the first flange, and other flanges.