Port Size: 1/4 NPT
Input: 4-20mA
Bellofram Proportional Valve 969-710-001
People who bought this item also viewed
WANERF Overflow Valve BSG-06-2B2
KOMPASS Piston Pump PVS22-A1-F-R-10
Eaton Vickers Vane Pump V20-1P13P-1B11
DUPLOMATIC Gear Pump GP3-0264R01F-20N
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Minpear Turbine Reducer XLD2-23-0.75KW
MERKEL Oil Seal ES 200-230-45
Recent related posts
-
08/21/2020
A newly installed air conditioner trips as soon as it is plugged in. What's the matter
This question is about the first use of newly purchased appliances. This question actually asks two questions: First, the newly installed air conditioner trips as soon as it is plugged in. Why?
-
09/05/2020
Common sense of micro vacuum pump
The so-called vacuum refers to a gas state with a pressure lower than 101325Pa in a given space. In the vacuum state, the lean degree of gas is usually expressed by the pressure value of the gas. Obviously, the smaller the pressure value, the thinner the gas. There are various vacuum pumps in the industry. There are prescribed test methods for the performance of various pumps. The main parameters are:
-
06/14/2020
Magnetic suspension refrigeration technology is expected to become the mainstream trend of refrigeration in the future
Magnetic suspension refrigeration technology is expected to become the mainstream trend of refrigeration in the future "With the elaborate construction of data center refrigeration systems,
-
09/21/2020
Refrigeration system failure symptoms
Symptoms of refrigeration system failure 1. Detection of pressure and temperature of refrigeration system (1) The pressure concept of the refrigeration system The refrigeration system can be divided into high and low pressure during operation. The high pressure section is from the discharge port of the compressor to before the throttle valve. This section is called the evaporation pressure.
-
11/11/2021
Different Types of Pressure Transmitters, Working Principle, and How to Select Pressure Transmitter
Pressure transmitter is a kind of pressure measuring instrument widely used in many transmitters. It is widely used in petroleum, chemical, metallurgy, food, electric power, medicine, papermaking, textile and other industries.
-
06/14/2020
Working principle of inverter compressor
The principle of inverter compressor inverter controller is to convert the alternating current in the power grid into a square wave pulse output. By adjusting the frequency of the square wave pulse (that is, adjusting the duty cycle), the speed of th ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/31/2024
How Does a Wood Stove Fan Work?
Wood stoves have been a reliable source of warmth for centuries, providing a cozy atmosphere during chilly days.
-
08/29/2020
SPK Fluid reliable compressed air escort
SPK Fluids is a global supplier that provides highly specialized and engineered solutions, with branches in 35 countries and operations in more than 150 countries around the world.
-
06/14/2020
Refrigerating oil use characteristics and performance requirements
Refrigerating oil use characteristics and performance requirements Refrigerating machine oil is mainly used to lubricate the parts that need to be lubricated in the freezing machine, and is closely related to the running performance and service life of t ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់