Camozzi Proportional Valve ER104-92AP
Type: Proportional Valve
Brand: Camozzi
There is no price at present, you can Request a Quote
Input signal: 4-20mA
Port diameter: Rc1/4
Type: Proportional Valve
Brand: Camozzi
There is no price at present, you can Request a Quote
Type: Proportional Valve
Brand: Camozzi
There is no price at present, you can Request a Quote
KITZ Check Valve UO-DN40
KINGST Overflow Valve DB-03G-3
KCL Vane Pump VQ35-76-F-RAB-01
Danfoss Gear Pump SNP1NN/012L(R)01AA03NN
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
AirTAC Air Cylinder MBLC50X450
SAMYOUNG Capacitor 35V 390UF
Schneider CPU PLC BMEP585040
ORIX Fan MDA1225-24G
07/23/2020
1. The refrigeration compressor cannot start normally Maintenance ideas 1. First, check whether it is caused by low power supply voltage or poor connection of the motor circuit. If it is indeed that the grid voltage is too low, restart after the grid voltage returns to normal: If the line is in poor contact, the connection between the line and the motor should be detected and repaired.
01/15/2021
Operation process of automobile air-conditioning refrigeration system and the role of pressure switch From top to bottom, automobile air conditioners are mainly composed of blowers, evaporators, pressure switches, dryers, expansion valves, condensers, 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐
08/15/2020
Cold storage evaporators can be divided into two categories: air coolers and cooling pipes. Air coolers are generally used in cooling rooms, freezing rooms and cooling reduction rooms for cooling objects.
06/09/2023
If you’ve ever heard your AC making noise when off, it can be a bit unnerving. You may wonder what's causing the noise and what you can do to fix the problem.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
09/06/2020
The application of frequency conversion energy saving in the crude oil extraction industry is mainly manifested in various pumps. In order to ensure the reliability of production, all kinds of production machinery have a certain margin when they are designed and equipped with power drives.
11/10/2022
Industrial fans, which can efficiently push a large amount of air and generate super-large air volume. This creates a circulating airflow field in the space.
06/23/2020
1.If it is because of the weather, you need to change the refrigerator to another location. 2. When used in winter, you can turn on a compensation switch in the refrigerator. 3. It is necessary to check whether the compressor is damaged. 4. If the modulation gear is incorrect, you can adjust the gear higher. 5. If the refrigerant is not enough, the problem of non-refrigeration can be solved after the fluorine content is added.
06/14/2020
Do you know the working principle and advantages of the ground source heat pump What is a ground source heat pump?
08/27/2020
Content covered by compressor overhaul Compressors generally need to be overhauled after 12,000-26,000 hours of operation. In addition to all the work required for intermediate maintenance,