Series:TSB
Size:90
TWD Speed Reducer TSB090
People who bought this item also viewed
Faunc Servo Motor A06B-0212-B300
JOHNSON Electric Motor 1080222
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Recent related posts
-
09/09/2020
Harmfulness of air compressor motor direct full pressure start and the benefits of motor soft start cabinet
With the development of my country's economy, the application of motors is increasing, and people's attention is paid to the starting method of motors. Generally speaking, the motor soft start cabinet should be used when the motor power exceeds 30KW, otherwise it will seriously affect the operation of other equipment in the power grid and damage the motor itself.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/11/2020
The temperature status and faults of the unit components of various commercial central air-conditioning systems
When the commercial central air-conditioning system is overhauled, temperature inspection and testing are very important, because the unit components of the entire central air-conditioning system have a normal temperature range, beyond which it is an abnormal state.
-
11/09/2023
Centrifugal Fan vs. Axial Fan: Understanding the Differences and Applications
Centrifugal fans and axial fans are two common types of fan systems used in various industries and applications.
-
09/14/2020
Application of oil bath air filter in air compressor industry
Cement plants have many production and grinding processes, and the ambient air contains high dust concentrations. The original design of dust removal filter device used in air compressor is mostly paper filter element dust removal.
-
09/10/2020
Working principle of okmarts.com air compressor water-cooled screw air compressor
There are many models of okmarts.com air compressors. Low pressure rotor. Electronic motor, the main components of LG-1.2/8LG-33/13 are: air filter. Low-pressure rotor intercooler. High-pressure rotors, rock drills, twin-screw air compressors, frequency conversion air compressors, after coolers, transmission parts, gear boxes, regulator control systems, safety valves and silencer shells, etc.
-
07/30/2020
Collection of various types of faults and troubleshooting methods for central air conditioning!
Collection of various types of faults and troubleshooting methods for central air conditioning
-
02/01/2023
What is Gear Ratio?
Gear ratio, i.e., the reduction ratio of the reducer, refers to the ratio of the instantaneous input speed to the output speed in the reduction mechanism, and is represented by the symbol "i".
-
06/14/2020
How about ultra-small refrigeration compressors Features introduction of ultra-small refrigeration compressors
Among the components of our refrigeration compressor, the compressor is very important, and an ultra-small refrigeration compressor is widely used in our equipment with a refrigeration capacity of less than 1KW, so today I will introduce you to us Some of 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜
-
06/14/2020
What are the causes of frost in refrigeration compressors
The importance of refrigeration compressors in the entire cold storage refrigeration system is self-evident, I believe everyone knows. Next look at the editor to teach you to turn around.