Minimum Breakdown Voltage: 500VDC
A mechanical switch operation which controls output pole connection
COSMO Relay D1A240000
People who bought this item also viewed
PARKER Relay SCPSD-400-14-27
TOGAMI Relay TJ-125-3F
JEL Relay S1C-225WDV
SIEMENS Relay 3TK2824-1AL20
Wurth Transformer 749118215
Hager Contactor ES210
CITEL Surge Protection Device DS44-385
Schurter Fuse 3403.0160.24
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve VF3130-5GS-02
Siemens Transmitter 7MF4033-3BA00-1AB7
TAIAN Relay RHN-10M 4.5-6.3A
HONTKO Encoder HPN-6A-120-2-C
YONGSUNG Relay YSLT-F00-52-12S
Recent related posts
-
01/11/2021
Japan Daikin, Hitachi and Mitsubishi Electric air-conditioning compressor comparison
First, take a look at Daikin. The use of high and low pressure cavity scroll compressor and swing compressor
-
12/17/2021
How to Reduce Noise of Air Compressor?
Air compressors can provide stable air flow with little pressure fluctuation, which has the advantages of stable rotation and high efficiency.
-
06/29/2020
What is the cause of compressor pipeline vibration
-
06/30/2020
Causes of compressor burnout
Causes of compressor burnout Common failures of compressors are mainly the following three: 1. Motor burned out; 2. Liquid shock; 3. Oil shortage caused by refrigeration oil. Today I will give you a detailed analysis of the cause of the motor burnout.
-
03/10/2021
Common faults
The motor of servo driver is unstable, and the speed is fast and slow. The main reasons for this kind of fault are as follows: 1.The servo driver parameters are not adjusted properly, and the regulator does not reach the best working state.
-
06/29/2020
Treatment of frost in crankcase when compressor head frost is serious
Treatment of frost in crankcase when compressor head frost is serious The frost on the cylinder head is caused by a large amount of wet steam or refrigerant sucked into the compressor. The main reasons for this situation are:
-
09/14/2020
Troubleshooting of high pressure air compressor
1-0.27/150 Type High Pressure Air Compressor Troubleshooting Method Fault Features Sound in the crankcase Possible cause a. The screw and nut of the connecting rod are loose. Whether the big-end bearing of the connecting rod is loose.
-
03/09/2023
Working Principle and Starting Modes of Soft Starter
Soft starter is a motor control device that integrates soft starting, soft parking, and light load and energy saving of motor, and multiple protection functions.
-
06/27/2022
How to Test an Encoder with a Digital Multimeter
A basic multimeter can be utilized to measure the encoder’s parameters. Bear in mind that a digital multimeter can measure the average duty cycle, frequency, peak voltage, and average voltage of an encoder.
-
08/02/2020
What is the four-pipe air conditioner Under what circumstances
Four-pipe air-conditioning means that the air-conditioning box is equipped with cold coils and hot coils at the same time. Each group of coils is fed one time, a total of four, so it is called four-pipe.