UNION Relay SDA3-280RVR
People who bought this item also viewed
Riken Relay RAB-150N
JEL Relay S1C-225WDV
TOGAMI Relay TJ-125-3F
TRIAD Transformer F-215U
Terasaki Circuit Breaker TZ100CC
Siemens Contactor 3RT2518-2AF00
Ferraz Shawmut Fuse FR22AM50V100P
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Amico Check Valve 9930X DN300
Schneider Contactor LC1D186F7
KOGANEI Air Cylinder MRGH6X50
Recent related posts
-
02/27/2022
Four Things about the CT (Current Transformer)
The CT (Current Transformer) is a component used to detect current signals, which is based on a transformer.
-
06/13/2020
Characteristics of rolling rotor compressor
Characteristics of rolling rotor compressor (1) Rolling rotor rotary compressor is a commonly used compressor for room air conditioners (2) Compared with the reciprocating piston compressor, it has the following characteristics:
-
07/18/2020
The common fault analysis of refrigeration compressors is here!
Working condition and adjustment of refrigeration system of low temperature chiller Refrigerators are now widely used in the refrigeration industry, and the refrigerant is usually R22 (also R404a). In order to facilitate operation and maintenance and reduce the installation location, the refrigeration compressor, oil separator, water-cooled shell and tube condenser, filter drier
-
06/13/2020
Two methods of evacuating the refrigeration system
Vacuuming is an indispensable important process before charging refrigerant in the production or maintenance of refrigeration equipment. That is, the process of removing the non-condensable gas and moisture in the system pipeline by connecting the vacuum 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘
-
01/21/2024
Central Air Conditioning: Types, Components, and Brands (including Mitsubishi Electric, Daikin, York, Carrier, etc.) (Part 2)
The air conditioning system was first invented by Willis Carrier, the founder of Carrier Company. The technology gradually spread in America and Europe.
-
03/18/2021
Parameter setting method of servo motor driver
The larger the setting value, the higher the gain and the greater the stiffness. Under the same frequency command pulse condition, the position lag will be smaller.
-
09/06/2022
How to Select Overflow Valve
The nominal pressure of the overflow valve is determined by the operating pressure, the service temperature range of the safety valve is determined by the operating temperature
-
09/06/2020
The energy saving of air compressors starts with the gas tank and pipeline!
Energy saving principle After the compressed air is discharged from the compressor, it needs to be transported to the application place through the air tank and pipeline. In the field of use, there are problems with gas storage tanks and pipelines
-
07/05/2022
8 Common Concerns about Magnet Pumps
Magnet pumps are very different from typical sealed pumps. Therefore, it is natural for people to have concerns. I narrowed the list to 8 questions that are commonly asked with regard to mag-drive pumps.
-
09/03/2020
What is the maximum flow condition of a centrifugal compressor
The working condition when the flow reaches the maximum is the maximum flow working condition. There are two possibilities for this working condition: