03/08/2022
What’s the Difference between Semi-Hermetic Compressors and Hermetic Compressors?
In the hermetic compressor, the motor and the compressor share the main shaft (reciprocating type)
-
09/10/2020
Lubrication characteristics and requirements of mobile air compressors
1. The characteristics of the mobile air compressor are: (1) The mobile air compressor should be easy to move frequently, the working conditions are changeable, and the load changes greatly. (2) Mobile air compressors are mostly heavy-duty, medium-speed or low-speed transmission, and most require frequent starting and often withstand shock loads;
-
06/30/2020
Analysis of the main advantages of Copeland compressors
Analysis of the main advantages of Copeland compressors Copeland compressors not only have a high reputation, but also stand out among well-known brands. It is precisely because Copeland compressors have the advantages that most compressors have or do not have.
-
08/15/2020
The layout principle of Freon refrigerant pipeline
The main feature of Freon refrigerant is that it dissolves with the lubricating oil. Therefore, it must be ensured that the lubricating oil from each refrigeration compressor can return to the refrigeration compressor after passing through the condenser,
-
07/27/2020
The refrigerator compressor keeps beeping after cleaning, but it is not cooling. What's the problem?
he compressor keeps ringing, so it keeps working. There is no intermittent start and stop sound, which means it has been working hard to refrigerate, but now there is no refrigeration output.
-
02/23/2020
There are really many kinds of air-conditioning compressor patterns revealed
Air-conditioning compressors have always been dubbed the "heart" of air-conditioning by industry insiders, but many small partners do not understand the important object of air-conditioning, and they are also very curious. What does the air-conditioning compressor look like? How are they different? Today, I will briefly explain to the friends the different classifications of air-conditioning compressors
-
07/17/2020
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit A central air-conditioning system in a public area uses a screw chiller. During operation, a copper tube in the evaporator leaks due to a malfunction. After further inspection by the technical staff, it was confirmed that the fault was leakage of the copper pipe of the evaporator of the chiller.
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,
-
12/26/2022
What is a Programmable Logic Controller?
The programmable logic controller (PLC) is a digital operation electronic system specially designed for application in industrial environment.
-
08/17/2020
How to clean the return air duct of central air conditioning
Today, the editor of okmarts.com mainly introduces some of the most commonly used and basic cleaning procedures for central air-conditioning. I hope it will be useful to everyone!