08/25/2020
How to correctly take out ammonia refrigerant when repairing refrigeration parts
First, prepare all tools and emergency supplies before operation. Such as ammonia tanks or a certain number of ammonia bottles, scales, connecting pipes, fitter tools, gas masks, rubber gloves and first aid medicines.
-
09/16/2020
Analysis of Frequency Conversion Technology in the Application of Air Compressor System
1. Operation principle and analysis of air compressor As far as okmarts.com is concerned, the main equipment currently being renovated is basically a traditional screw air compressor. The air compressor is a load with a large moment of inertia.
-
07/17/2020
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit A central air-conditioning system in a public area uses a screw chiller. During operation, a copper tube in the evaporator leaks due to a malfunction. After further inspection by the technical staff, it was confirmed that the fault was leakage of the copper pipe of the evaporator of the chiller.
-
06/13/2020
Expansive survey of Global Air Compressor Market 2020
Manufacturing Healthcare Oil and gas development Besides, the report discusses the most integral market element, the competitive scenario
-
09/28/2022
What is Positive Displacement Pump?
<strong>Positive displacement pump</strong> is also known as a volumetric pump, which uses the periodic volume changes of the working chamber (pump casing or cylinder) in the pump to transport the liquid.
-
07/18/2020
The role of precision chillers in various industries
Piston refrigeration compressor liquid hammer process and reasons for liquid hammer 1. Introduction The phenomenon that liquid refrigerant and/or lubricating oil is sucked into the compressor cylinder with the gas and damaged the suction valve plate
-
07/14/2020
What's wrong with the freezer not cooling
1. Test the power cord with an electric pen. The broken power cord of the freezer is also a cause of non-refrigeration. For this situation, we need to check whether it is a power problem. The general approach is to open the door and observe whether the lighting lamp in the box Light up. Look for signs of damage to the wires, such as being bitten by a mouse.
-
02/07/2023
Pros and Cons of Pneumatic, Electric and Hydraulic Actuators
The actuator used in the control valve are nothing more than pneumatic, electric, and hydraulic (electro-hydraulic) type.
-
09/05/2023
Variable Speed Heat Pump: The Efficient Way to Heat and Cool Your Home
A variable speed heat pump is a heating and cooling system that can adjust its output based on the needs of your home. Unlike traditional HVAC systems
-
07/16/2020
Compressor overheating
The compressor is overheated, causing it to stop shortly after start-up (protector action). Please check whether it is:; Insufficient or excessive refrigerant, please fill the leak and evacuate, add enough refrigerant or release excess refrigerant. The capillary assembly (including the filter) is clogged and the suction temperature rises. Please replace the capillary assembly.