There is no price at present, you can Request a Quote
Minimum detection object:diameter 14 mm
Optical axis distance / lens diameter:10 mm / diameter 4 mm
Effective opening angle:+/- 2.5 degree (at a detection distance of 3 m or more)
Operating distance:0.1 to 7 m
Response time (ms):
ON OFF:19 * 1
OFF ON:59 * 1
light source:Infrared LED (850 nm)
Operation mode:ON when all beam axes are receiving light
OSSD output:
Output type:PNP / NPN 2 each output can be converted according to connector cable
Load current:500 mA * 2
Residual voltage (when ON):2.5 V (at 7 m cable)
Leakage current:100 ?A * 3
Maximum load capacity:2.2 ?F (at load resistance 100))
Load connection resistance:2.5 ohm * 4
Output for non-safety circuits:
AUX
Interlock release waiting output
Alarm output
Light In / Light Out
Status output 1, 2:PNP / NPN with automatic conversion function output max. 50 mA
Blanking light output:Can connect white incandescent lamps (24 VDC, 1 to 7 W), LED lamps (load current 10 to 300 mA) * 5
Enter
EDM input:Short-circuit current 10 mA
Standby input
Reset input
Blanking input 1, 2
Override input:Short-circuit current 2.5 mA
protect the circuit:Reverse power protection, short-circuit protection for each output, surge protection for each output
Meet specifications:
EMC:EMS:IEC61496-1, EN61496-1, UL61496-1
EMC: EN55011 ClassA, FCC Part15B ClassA
Safety:
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, UL61496-2, EN61496-2 (Type 4 AOPD)
IEC61508 (SIL3), EN61508 (SIL3), IEC62061 (SIL3), EN ISO13849-1: 2015 (Category 4, PLe)
UL508
UL1998
Rated:
voltage:24 VDC +10%, -20%, ripple (P-P) 10% or less
Consumption current (mA):
When the center indicator is on:
launcher: 104 * 6
receiver: 131 * 6
When the center indicator is off:
launcher:145* 6
receiver:109 * 6
Environmental resistance:
Enclosure protection level:IP65 (IEC60529)
Overvoltage category:II
Ambient light:Incandescent: up to 5,000 lux, daylight: up to 20,000 lux
Use ambient temperature:-10 to +55 degree C (no freezing)
Ambient storage temperature:-25 to +60 degree C (no freezing)
Use of ambient humidity:15 to 85% RH (non-condensing)
Storage environment humidity:15 to 95% RH
Earthquake resistance:10 to 55 Hz, double amplitude 0.7 mm, 20 sweeps each in X, Y, and Z directions
Impact resistance:100 m / s2 (about 10 G), 16 ms pulse, 1,000 times each in X, Y, and Z directions
material:
Body shell:aluminum
Upper cover / lower cover:Zinc die casting
Front shell:Polycarbonate, SUS304
weight:
launcher:2050 g
receiver:2060 g
* 1 During serial connection, the response time (ON OFF) is the sum of the response times of all connected SL-V units. When three SL-V32H (32 optical axis), SL-V24H (24 optical axis) and SL-V12L (12 optical axis) are connected in series, the response time of a single machine is 10.3 ms, 9.2 ms, 7.6 ms.
Response time (ON OFF) = 10.3 ms + 9.2 ms + 7.6 ms = 27.1 ms. Response time (ON OFF) = 27.1 ms + 40 ms = 67.1 ms.
* 2 300 mA or less when used at an ambient temperature of 45 to 55 degree C.
* 3 Including power-off or power-line disconnection.
* 4 For normal operation, make the connection resistance of the equipment connected to the OSSD output (except the connection resistance of the optional dedicated cable) 2.5 ohm or less. When using NPN output, when the cable length is more than 15 m and the load current is more than 200 mA, it should be less than 1.0 ohm.
* 5 When used at an ambient temperature of 45 to 55 degree C, white incandescent lamps (24 VDC, 1 to 3 W), LED lamps (load current 10 to 100 mA).
* 6 When the AUX output (red wire of the transmitter) and the EDM input (red wire of the receiver) are short-circuited, plus the following conditions, the transmitter's current consumption will increase by 10 mA from the above value, and the receiver's current consumption will decrease. 10 mA. (The total current consumption of the transmitter and receiver does not change.)
? When using PNP output cable and OSSD is OFF ? When using NPN output cable and OSSD is ON
KEYENCE Light Curtain SL-V95FM
There is no price at present, you can Request a Quote
People who bought this item also viewed
YINGB Light Curtain GMJD-06-4-B1
YINGB Light Curtain GMJD-04-4-B1
Rockwell A-B Sensor 872C-J2N12-A2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HENGSTLER Encoder RI58-O/64ES.41KB
Delta PLC HostDVP30EX200R3
BANDO Belt A-400
Recent related posts
-
11/25/2022
What is Visual Flame Detector?
On the basis of traditional flame detectors, image-type flame detectors combine intelligent camera control technology and intelligent image processing technology.
-
07/05/2020
Is Hitachi central air conditioning good okmarts.com tells you how powerful Hitachi compressors are
Is Hitachi central air conditioning good okmarts.com tells you how powerful Hitachi compressors are ? I saw many articles about Hitachi compressors, various parameters and terminology, and simply summarized the following points
-
06/23/2020
Advantages and disadvantages of Hitachi central air conditioning
At present, the central air-conditioning of the refrigerant system is still the best done by Japanese brands. When it comes to Japanese central air-conditioning, one has to say that Hitachi, one of the Japanese air-conditioning BOSS, is a well-known international central air-conditioning brand. Most air conditioners now use scroll compressors as the core of power, and the world’s first scroll machine for air conditioning was manufactured by Hitachi in 1983.
-
07/02/2020
Meiyoule compressor MTZ-100 latest promotion
Meiyoule compressor MTZ-100 latest promotion Product Features of MYO100 Compressor: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably. 2. The high-performance standard bearings and motors of Meyer compressors can adapt to the use of new chlorine-free refrigerants.
-
09/09/2020
How to provide air source for air compressor
Is the air compressor better for centralized air supply or more energy-saving for point-by-point air supply; for equipment with small air consumption and low pressure, it may be economical to install a pressure reducing valve to work.
-
08/28/2020
Learn about refrigerated dryers
In order for the compressed air system to function properly, the air must be dry. This means that before entering the air network, the air must have no liquid moisture and low relative humidity.
-
05/30/2022
How Do I Test the Power Supply in My Computer?
Testing a power supply is an important step when troubleshooting many issues, most obviously when your computer is having trouble starting.
-
06/13/2022
Working Principle and Advantages of HMI?
"HMI" stands for Human Machine Interface. These devices are also known as Man Machine Interface (MMI), Operator Interface Terminal (OIT), Local Operator Interface (LOI)
-
01/02/2021
The Danfoss DNA
Our DNA is about keeping the essence of Danfoss and sits right at the heart of our Core & Clear strategy. The Danfoss DNA The Danfoss DNA Our DNA determines who we are,and where we want to go.It is our essence. Our irreducible core.The foundation of ou 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧֚ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
03/09/2022
Why is Your Refrigerator Start Relay Bad
Refrigerators have been necessary for people’s daily life and there are probably some problems with your refrigerators