Product name | DC Fan |
Frame material | Plastics |
Series | San Ace 80 |
Frame size(mm) | Square - 80mm L x 80mm H |
Frame thickness | 20.00mm |
Rated voltage[V] | 24VDC |
Rated current[A] | 0.07 |
Rated input[W] | 1.68 W |
Rated speed[min-1] | 2300 |
Max. airflow[m3/min] | 0.67 m3/min |
Max. airflow[CFM] | 23.7 CFM |
Max. static pressure[Pa] | 18.6 Pa |
Max. static pressure[inchH2O] | 0.075 |
SPL[dB(A)] | 25 dB(A) |
Expected life[h] | 60000/60℃ (90000/40℃) |
Sensor type | With a pulse sensor |
IP rating | - |
PWM control function | No |
Bearing Type | - |
Fan Type | - |
Features | - |
RPM | - |
Termination | - |
Operating Temperature | - |
Approval Agency | - |
Weight | - |
Voltage-Rating: 24VDC
Size/dimensions: square-80mm long x 80mm high
Width: 20.00mm
Air flow: 23.7 CFM (0.664m3/min)
Static pressure: 0.075 inches of water column (18.6 Pa)
Bearing type: ball
Fan type: tube shaft type
Features: Speed sensor (tachometer)
Noise: 25.0 dB (A)
Power (W): 1.68W
RPM: 2300 RPM
Termination: 3 leads
Intrusion protection:-
Working temperature: -4 ~ 158°F (-20 ~ 70°C)
Weight: 0.22 lbs (99.79g)
We can also provide the following models
9GA1412D90021
9GA0512J7021
9HV0548A40011
9HV0624D4D011
9WL0612E4021
109BG24S027-1
9GV1405L2021
9GV1324B40011
9HV0424S0D001
9GV0812A1001
109BC24F0027
9GA0524W0D013
9GA1212C201
9HV1505K4D001
9GV3624G0D013
9HV5724F0D001
9BF24K0022-1
9HV1205G2D011
9GV1248C7001
9HV1205C7D011
9HV0412G90021
9HV0305S5D011
9HV1705K102
9GV5748D7D0011
9GA2024D70011
9GA0948C0D001
9GA0405L2011
9GA1512J9001
9GV0405A1D0011
9WL1212S5H02
9GV1512G10011
9GV1205C2D011
9GV0424G3002
9HV0405A9023
9GA1448L0D0011
9GV1348S40021
9WV1212E1002
9GA3624H6D0011
9WL5748G6D01
9LG0924H3002
9HV2012M5D013
9HV1712J1D0011
9GV1412A50013
9GV1424E4001
9HV0305J90013
9GA1748J7023
9GA5705A30023
9GA5724F20021
9GV0524L0D01
9GA0405K9D001
9GA2048C10023
9GV0605A3D011
9HV5712A40023
9GV0524W6D0013
9GV1212B20021
9HV1724L201
9GV1312H1002
9WL0648H1H002
9GV2012W4023
9WL1448S102
9HV0424S4021
9GV4748H9023
9HV0924L00013
9GV5712L2001
9GV1248K3D0013
9HV1424B7D011
9WL5712M5H0011
109BJ12FC7-1
9GV1212L6D0013
9WL5748M1H01
9GV5712E1D001
9GV1448K30021
9HV1205L0D0013
9GV0524S2D0013
9GV0312K3021
9L5748F501
9GA0524S10011
9GV0812B60013
9HV1748L3013
9L0648S301
9GA1248A2023
9GA1224G9D013
9GA3612A602
9GA5724L3D013
9HV1424M2D0011
9GV0812C1D0013
9CRL1424H3001
9GA1248D3D011
9GA0848M70013
9GA1212D0D001
9HV1748W00011
For more information,please contact us freely
Sanyo Denki Fan 109P0824M601
People who bought this item also viewed
Nidec Fan C35129-51API
Ziehl Abegg Fan FN080-ZIQ-GL.V7P3
Sanyo Denki Fan 109L1424H5J04
Sanyo Denki Fan 109P0824H6D01
Sanyo Denki Fan 109P0424H6D11
Sanyo Denki Fan 9GA0712P1G001
ORION Fan OD280-24HB
Ebmpapst Fan 3956M
SUNON Fan KD0504PFB2-8
SUNON Fan PMD2409PMB1-A
Copeland Compressor ZR190KCE-TW7-551
COOPER Transformer VPH1-0190-R
TENGEN Contactor CJ19-63/21
Sesame Electric Motor 5IK60GN-S/UMTS
PARKER Filter G02852
Danfoss Sight Glass SGP12S
SIEMENS Capacitor 630V 4.7UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch NS M3TE1SMK-F41
SANWU Belt SPA1457
BOURNS Encoder ECW1J-R24-BC0024L
Siemens Sensor QFA3280.EWNC
Recent related posts
-
06/14/2020
What is the effect of pressure and temperature on the refrigeration system
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
08/15/2020
What should I do if wall cracks appear after the cold storage is built
After the construction of the cold storage project, there may be many problems. For example, we have seen a lot of news recently. It is said that the wall cracks appeared after the construction of the cold storage
-
08/20/2020
Trouble phenomenon the air conditioner is not cooling, the outdoor unit starts and stops frequently
When the air conditioner is frequently used in summer, many friends will encounter this problem, that is, the outdoor unit of the air conditioner frequently starts and stops, but the indoor unit is not cooled.
-
08/28/2020
What are the principles of air compressor frequency conversion How to apply
As we all know, the application of frequency conversion air compressors on the market is becoming more and more extensive.
-
08/23/2022
Ways to Increase Stepper Motor Torque and Select Stepper Motor
Reduce the number of turns to reduce inductance L: select the motor with small inductance L from the standard products of the motor manufacturers, the rated current will increase.
-
06/19/2022
How Does a VFD Work?
The first stage of a Variable Frequency AC Drive, or VFD, is the Converter. The converter is comprised of six diodes, which are similar to check valves used in plumbing systems.
-
06/13/2020
The structure of the central air conditioner is relatively complicated
The structure of the central air conditioner is relatively complicated. During use, the compressor noise is often accompanied by vibration. The vibration will increase the decibel of the noise, and the two affect each other. However, if the sound of vibra 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ
-
06/13/2020
Centrifugal refrigeration compressors are mainly used for air conditioning in large buildings, Less demand.
Centrifugal refrigeration compressors are mainly used for air conditioning in large buildings, Less demand. In recent years, large-scale infrastructure projects have been launched, and centrifugal refrigeration compressors have become a hot spot of concer ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់變ᩄ ꋔྦ 瑉浥
-
07/24/2020
Classification, principle and use of refrigeration compressors
Classification, principle and use of refrigeration compressors<br></br> The function of refrigeration compressor:<br></br> The refrigeration compressor is the "heart" of the refrigeration system. It absorbs the refrigerant vapor from the evaporator, increases the pressure and discharges it to the condenser, so that the refrigerant circulates in the system. Can be used in refrigeration systems and heat pump systems
-
10/17/2021
Maintenance of Absolute Encoders
What are the precautions for maintenance of rotary encoders? Rotary encoders are used as speed and displacement feedback sensors, which are mainly applied in servo motors, asynchronous motors