Honeywell Sensor SS94A1H
Type: Sensor
Brand: Honeywell
Operating Supply Current:30 mA
Maximum Output Current:1 mA
Operating Supply Voltage:12 V
Type: Sensor
Brand: Honeywell
Type: Sensor
Brand: Honeywell
Honeywell Sensor VF20-3B65NW
Honeywell Sensor AF20-B65
Honeywell Sensor FE5F-3MC6-M
Banner Sensor QS30LD-79194
Banner Sensor QS12VP6LV
Keyence Sensor LR-ZH500C3P
Banner Sensor SM2A30SRL
Dwyer Transmitter DPT-A02
Honeywell Flame Detector BC1000A0220U
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TROMBETTA Relay 684-2461-212-079-1
COSEL Power Supply LFA150F-15-SR2Y
SMC Solenoid Valve VG342-2G-06A
TOWA SEIDEN Switch FLD-6SA-4P
06/14/2020
Piston refrigeration compressor classification? According to the refrigerant used, piston refrigeration compressors are divided into ammonia compressors and freon compressors. Ammonia compressors are mostly used as hosts in large and medium-sized refrige 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
07/23/2020
1.Introduction to the properties of R410a refrigerant<br></br> 1. R410a is a HFCs refrigerant mixed with two working fluids of R32 and R125 at a mass fraction of 50% and 50%. It is a near-azeotropic mixture (pseudo-azeotrope), and its thermal performance is close to a single working fluid.
07/04/2020
okmarts.com platform compressor technology experts tell you why the air conditioner can be cooled In the summer, I believe that many people's feelings must be hot, scorching heat, sweating, etc. At this time, air conditioning is naturally essential equipment. If the air conditioner in your home is not cooling, then the air conditioner becomes a decoration.
10/30/2021
At present and in the future, the maintenance of the electrical control equipment, VFD (Variable Frequency Drive) will become the professional knowledge that all electricians need to master.
11/10/2021
Programmable logic controller (PLC) plays an important role in factory automation (FA). The continuous development of technology has greatly promoted the improvement of control function and control level of the control system based on PLC
12/02/2021
When adjusting the transmitter, please turn off the protection setting, which is usually the red switch in front of the meter and its status may be ON or OFF.
08/08/2020
Water-cooled industrial chillers and air-cooled industrial chillers are generally used in long-term working conditions. If there is a little leakage in the refrigeration system, air will enter the refrigeration system of the industrial chiller over time.
09/08/2022
The following article introduces some differences between brushed motors and brushless motors in terms of working principle and performance, hoping to deepen your understanding of them.
08/19/2020
Inferior refrigerants will affect the performance and stability of the system, and more seriously will cause damage to system components and compressors. The following methods can be used to distinguish whether it is a low-quality refrigerant:
07/11/2020
Working flow chart of screw air compressor In the first step, the air compressor sucks the surrounding air through the air filter to make it enter the compression host.