Input voltage:300/415/460V
Input current:5.7A
Input inspecting power:3.8/4.1/4.5KVA
Input frequency:50/60Hz
Output voltage:300/415/460V
Output current:6A
Output inspecting power:3.9/4.3/4.8KVA
Output frequency:0-250Hz
Allen Bradley Servo Drive 1336-B003-EDD-L3
People who bought this item also viewed
Allen Bradley Servo Drive 2098-DSD-HV100-DN
Allen Bradley Servo Drive 1394-SJT22-A
Allen Bradley Servo Drive 1394-SJT05-A
Allen Bradley Servo Drive 2098-DSD-010X-DN
Schneider Servo Drive LXM52DD30C41000
Mitsubishi Servo Drive MR-J2-100A-S24
Fanuc Servo Drive Module A06B-6079-H307
Panasonic Servo Drive MHDA303D2A49
Mitsubishi Servo Motor HF-MP053BD
YUKEN Servo Valve LSVHG-04-900-180-ET-1056
Siemens HMI 6AV2 124-0XC02-0AX0
COSEL Power Supply PBA15F-48-N
INTEL NIC Card E810-CQDA2
INFINEON IGBT Module FD300R12KS4_B5
Nais Relay HC3-HL-AC120V-F
NARADA Battery 6-GFM-155HR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Keyence Sensor SJ-M070G
ARK Air Cylinder KAND-32-5-A-P-A
Mitsubishi Compressor ANB33FEYMT
Schneider Contactor LC1D25EHE
Recent related posts
-
09/02/2020
There are 8 reasons for the high fuel consumption of air compressors, some of which can't be thought of!
Run oil In our daily work, we often encounter the problem of air compressor running oil. In addition to the quality of the oil itself, what other reasons can cause the running oil? In practice, engineers have summed up several reasons that can cause oil running. Let's share with you.
-
08/05/2020
System handling guide after the refrigeration compressor is damaged
The refrigeration compressor in the refrigeration system cannot be directly replaced with a new compressor after it is damaged, because there may be some incentives for the refrigeration compressor to be damaged in the system
-
08/10/2020
Precautions for the use of refrigeration compressor overload protector
Overload protectors for compressors used in air conditioners generally use snap-on bimetallic protectors, consisting of a heating wire, a bimetallic sheet and two static contacts, which are connected in series in the compressor circuit.
-
06/14/2020
Central Air Conditioning Maintenance: Basic Procedure for Chiller Failure Treatment
In order to ensure the safe, efficient and economical long-term normal operation of the chiller, it is very important to discover the hidden dangers of failures as early as possible during its use. Today, the editor of Service will give you an analysis o 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ
-
07/15/2023
What is a Semi-Hermetic Compressor? Everything You Need to Know
If you're in the refrigeration or air conditioning industry, you may have come across the term "semi-hermetic compressor." But what exactly is a semi-hermetic compressor, and how does it differ from other types of compressors?
-
08/31/2020
Market application and prospect analysis of air compressor waste heat recovery
Background With the rapid development of industry and economy, people's demand for energy is also increasing day by day. With the endless exploitation of human beings, the reserves of fossil fuels are decreasing day by day, and the world energy crisis is increasing day by day. Subsequently,
-
06/14/2020
How to protect the refrigeration compressor, you must master the following knowledge
When the compressor is running, some abnormal conditions may occur, such as: the discharge pressure is too high, the suction pressure is too low, the oil pressure is insufficient, the motor is overheated, and excessive liquid enters the cylinder. If an ab 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/14/2020
The reason for the frost on the compressor air inlet is here!
The reason for the frost on the compressor air inlet is here! Frost on the air inlet of the cold storage compressor is a very common phenomenon in the refrigeration system. Under normal circumstances
-
08/20/2020
How to judge the fault based on the indicator light of the ice machine
1. The power indicator light keeps flashing quickly and the machine does not work: The cause of the failure: the water temperature probe is open. Repair method: Open the rear cover, open the cover of the electric control box above the compressor, find a three-core connector, check if there is any dropout or poor contact, then reconnect it.
-
03/16/2023
The Installation and Maintenance of Water Pump
1.Check whether the water pump motor is in good condition. 2.Good airtightness should be ensured between water pump and pipeline.