Bosch Rexroth Servo Drive HMS01.1N-W0054-A-07-NNNN
People who bought this item also viewed
Bosch Rexroth Servo Drive DMA 030A-3301-D
Schneider Servo Drive LXM28AU15M3X
Sanyo Denki Servo Drive 65BA030VDT15
Yaskawa Servo Drive SGDM-50AD-HQ1A
Sanyo Denki Servo Drive PY2A015E0XXYPH2
Inovance Servo Motor ISMH2-30C30CD-A331Y
Schneider HMI HMISTU855T
Tamagawa Seiki Encoder TS5313N512
Omron PLC CS1W-OA201
FESTO Input Output Module CP-FB09-E
UNION Relay SDA1-215R
Kamcy Battery 802040-650mAh-3.7V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
TAICIN Vane Pump VDV-1B-F54-D-35
Copeland Compressor ZPJ61KCE-TFD-496
Yaskawa Servo Motor SGMPH-01AAAGB61
AirTAC Air Cylinder MD32X15-S
Recent related posts
-
07/02/2020
Meiyoule compressor MTZ-100 latest promotion
Meiyoule compressor MTZ-100 latest promotion Product Features of MYO100 Compressor: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably. 2. The high-performance standard bearings and motors of Meyer compressors can adapt to the use of new chlorine-free refrigerants.
-
09/04/2020
Have you heard of the 6S management of the compressor station on-site
For compressor users, on-site management is one of the daily management content of each enterprise.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/13/2020
Business management logic of cold storage management system
Business management logic of cold storage management system Nowadays, the development of the cold storage industry is fast, but the scale of the cold storage enterprises is uneven.
-
09/05/2020
What are the advantages and disadvantages of permanent magnet synchronous motors, and what are the developments
Compared with traditional induction motors, permanent magnet synchronous motors have unique performance. Mainly introduce the characteristics of permanent magnet synchronous motors, and analyze the research status and development trends at home and abroad.
-
08/15/2020
How to achieve low-cost operation of the freezer
Enterprise users who use refrigerators are more concerned about the cost of use. The editor of okmarts.com believes that only by saving energy can the cost of enterprise use be effectively saved.
-
09/07/2020
The most common problems and solutions of adsorption dryers!
Adsorption dryer is a very important part of the compressed air purification process. Whether it operates normally and whether it is running well is directly related to the quality of compressed air.
-
06/21/2022
10 Common Types of Transformer?
You might have come across various types of transformers in your daily life either knowingly or unknowingly. Different types of transformers are explained in brief in this article.
-
12/13/2022
What is a Memory Card?
A memory cards is an electronic data storage device used for storing digital information, typically using flash memory.
-
07/16/2020
Three factors determine the quality of cold storage
The size of the cold storage should be designed according to the highest amount of agricultural products to be stored throughout the year. This capacity is calculated based on the volume that the stored products must occupy in the cold storage, plus the aisles between the rows, the space between the stack and the wall and ceiling, and the gap between the packaging.