Fanuc Servo Drive A06B-6055-H106
People who bought this item also viewed
Fanuc Servo Drive A06B-6164-H333#H580
Fanuc Servo Drive A06B-6141-H011#H580
Fanuc Servo Drive A06B-6089-H101
Yaskawa Servo Drive SGD7S-330A10A
Mitsubishi Servo Drive MR-J2S-40B-PY096
LS Servo Drive L7-NA008B
Sanyo Denki Servo Drive RS1A30AA
YUKEN Servo Valve SVD-F102-20-15-20
Rockwell A-B HMI 2711P-B6M5D
LS Mecapion Encoder S58-10-0010ZO
Fuji PLC NP1L-RS1
MITSUBISHI Spindle Amplifier MDS-B-V1-10
CEACENT NIC Card AN8550-T2POE
TADIRAN Battery SL860-S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SCENERY Vane Pump S25V 21A-1C22R
YASKAWA Switch PSKH-010R25AV
SUNON Fan KD0505PFB3
Delixi Relay JSZ6-2 30s AC220V
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
12/06/2020
The working principle of oxygen generator (oxygen machine)
The working principle of oxygen generator (oxygen machine) The oxygen generator adopts pressure swing adsorption (PSA)-pressure adsorption and atmospheric pressure desorption (HP) method. After the raw material air is pressurized by an oil-free compressor,
-
02/01/2023
How to Reduce Gear Noise?
During gear transmission, gears scrape and contact each other, and repeatedly, resulting in noises.
-
08/19/2020
Precautions during use of industrial chiller compressor
One of the most important components in industrial chillers is the compressor. Compressor damage means that the chiller is scrapped. Therefore, the compressor is a very important consideration when choosing a chiller.
-
06/13/2020
Rotor compressor
The rotor compressor is driven by the engine or the motor (mostly driven by the motor), and the other rotor (also known as the female rotor or the concave rotor) is driven by the oil film formed by the main rotor through oil injection, or by the main roto 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然
-
03/17/2022
Dry Mode Vs. Cool Mode on Your AC
Now it is summer with the burning sun outside, what we can not leave is the air conditioner. Although air conditioners have entered most families, power consumption is attracting people.
-
08/24/2020
How to switch freely between cooling, heating and dehumidification modes
Nowadays, the air conditioner has become a must-have household appliance for every household. In different seasons, for us, we can adjust the temperature with our fingers and realize the switching of different functions.
-
01/28/2022
Refrigeration Compressor Frosting Reasons & Solutions
When we use the refrigeration compressor, there could be frosting. It’s a failure that we can solve.
-
11/07/2022
Guides to Choose a Thermostatic Expansion Valve
The thermostatic expansion valve, also known as the thermal expansion valve, controls the opening degree of the expansion valve
-
05/09/2022
Common Faults and Solutions of Solenoid Valve?
Detection method: First, measure its make-break with a multimeter. If the resistance value approaches zero or infinity, it indicates that the coil is short circuited or open circuited.