There is no price at present, you can Request a Quote
Kollmorgen Servo Motor 6SM 47L-3.000-G-S3-1325
There is no price at present, you can Request a Quote
People who bought this item also viewed
Kollmorgen Servo Motor AKM43E-BKC2R-00
Fuji Servo Motor GYH102C6-TC2
Panasonic Servo Motor MSMD082G1A
Yaskawa Servo Motor SGMGH-1AACA61
Yaskawa Servo Motor SGMJV-01ADA6C
Parker Servo Drive SDR-2-1000
ATOS Servo Valve E-RI-TEB-N-NP-01H 10
SIEMENS Actuator GCA161.1E
Invt UPS Power Supply HR1103L
JSCC Reduction Drive 80YT25GV22
Beckhoff Module ES4124
TYCO Relay OZ-SH-105LM1
SANYO Battery TEL-DAW600
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
CKD Air Cylinder SCG-00-50B-300
COSEL Power Supply AC6-OHHHH-00-F
KSCAP Capacitor 500V 6UF
AirTac Solenoid Valve 3V1-DC24V
Recent related posts
-
03/02/2021
Advantages of hollow axis servo motor
The diameter of hollow shaft can reach 40mm Compact size IP65 protection level Low rotor moment of inertia, high dynamic response characteristics
-
06/14/2020
Refrigeration compressor 11 ask, can you answer a few
1. Why control the impurity content and moisture content of the compressor and air conditioning system? Impurities enter the friction surface of the moving parts of the compressor pump body, which can cause abnormal scratches and wear. Impurities enter 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب
-
06/22/2023
What is a DC Compressor? A Comprehensive Guide
A DC compressor is an electrical compressor that is powered by direct current (DC) electricity.
-
06/14/2020
Does air conditioning and refrigeration rely on compressors or refrigerants, or both?
Does air conditioning and refrigeration rely on compressors or refrigerants, or both? This question seems to be asking whether to boil water in a kettle, whether it needs boiling water or a kettle. The compressor is a kettle, and the refrigerant is water 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
11/23/2021
Different Types of Pressure Transmitters
Pressure transmitter is a kind of instrument which can convert pressure variable into standard output signal. There is a functional relationship between the pressure variable and the output signal of pressure transmitter.
-
02/27/2021
The internal structure and characteristics of the micro servo motor
A miniature servo motor includes a small DC motor, a set of variable speed (reduction) gear sets, a feedback adjustable potentiometer and an electronic control board. Among them, the high-speed rotating DC motor provides the original power and drives the variable speed (reduction) gear set to produce a high torque output. The greater the gear ratio of the gear set, the greater the output torque of the servo motor, that is to say, the greater the weight it can bear, the lower the speed of rotation it will be.
-
07/30/2020
How to detect inferior refrigerants What's the harm
Inferior refrigerants will affect the performance and stability of the system, and even more serious will cause damage to system components and compressors. The following methods can be used to distinguish whether it is a low-quality refrigerant:<br></br
-
07/02/2020
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144
Introducing the performance characteristics of Meiyou Le Maneurop compressor MTZ144 Pictured here: the United States US Youle MANEUROP compressor MTZ144 Product features of MTZ144: 1. The design plan of the US Youle compressor is environmentally friendly, and the series compressors can run smoothly and reliably.
-
07/08/2020
For cold storage to be more energy efficient, this should be done!
For cold storage to be more energy efficient, this should be done! 1. The index for reducing the unit heat flow of the cold storage enclosure structure. In the design of the cold storage, the unit heat flow q of the outer wall of the low-temperature cold storage is generally about 11.63W. If the q can be reduced to 6.9W, for a 5000T~10000T class In low-temperature cold storage, it is estimated that the power cost can be reduced by about 10%.