SIEMENS Servo Drive Control Board 6SN1118-0DG13-0AA0
People who bought this item also viewed
SIEMENS Servo Drive 6SL3120-1TE28-5AA3
SIEMENS Servo Drive 6SL3210-5FE17-0UA0
SIEMENS Servo Drive 6SL3210-5CC16-0UA0
SIEMENS Servo Drive 6SL3210-5FE10-8UA0
MitsubishiServo DriveMR-J2M-BU4
Mitsubishi Servo Drive MR-S1-80-E31
Sanyo Denki Servo Drive QS1L01AJ0460MB01
Panasonic Servo Drive MCDLN35SE
Yaskawa Servo Motor USADED-13-YR21
Siemens HMI 6AV2 125-2JB03-0AX0
Johnson Controls Actuator VA7810-AGH-11
Omron PLC NX1W-CIF11
Newstart Speed Reducer PS190L1-3-P2-S2
MITSUBISHI Spindle Amplifier MDSBSPJ2-110
GRIS NIC Card RTL8821CU
SEMIKRON IGBT Module SKiiP 22NAB12T18
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Eaton Contactor DILM150(RAC48)
AirTAC Air Cylinder MAC16X175S
YUKEN Vane Pump PV2R12-19-41-F-RAAA-41
AirTAC Air Cylinder SC80X925S
Recent related posts
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/05/2020
What are the reasons for excessive oil content in exhaust gas and how to deal with it
1) The screw oil level is too high. If the oil level is too high, the fluctuation of the liquid level in the oil and gas barrels during the operation of the unit will cause a large amount of gas to enter the oi
-
06/13/2020
Rolling rotor compressor structure
Rolling rotor compressor structure
-
08/14/2020
What should I do if the screw compressor fails
Nowadays, in the summer, the use of air conditioners is increasing. If the screw compressor fails, how to repair it? First, check out where the fault is. After the inspection, repair or replace the damaged parts, as follows:
-
12/26/2023
Troubleshooting the "Air Conditioner Fan Not Spinning But Hums" Issue
When your air conditioner's fan refuses to spin but emits a distinctive hum, it can be a frustrating and perplexing situation.
-
01/16/2021
The working principle of piston compressor
The-working-principle-of-piston-compressor Working principle of piston compressor First, the working principle of the compressor When the crankshaft of the piston compressor rotates, the piston will reciprocate through the transmission of the co 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ର 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ 琉蒠S識器 直 囬ᐱ囸ᐱ嵭僦㠦ᐲᔇ僦囸ᐱ殺廼僦囬ᐱᙐ僦㠲ᐲ嵥僦直ᙧ僦㠲ᐲ令ᙐ僦㣮ᐲ嵭僦林ᙧ僦㣮ᐲ龍톺珵㥲ᐲ枬 퀖珵林춌珵蓄Cᴨ먢塚赺C直ᵘ먢塚㥲ᐲ礼藚C識直杴 器器蘯C礼器 垘ᒣ 識靖ﮰ﨤虣C器擜 ﮰ直杴 梅擩 祖斥 ﯤ未 ꍀᒥ똘Ḷ䠠 뤂ᐱ ᧪ᐲ 뤂ᐱ 㥲ᐲ 뤂ᐱ ᧪ᐲ 뤂ᐱ ᧪ᐲ 㗚ᐲ 嫜ི 젼Ḷ 뤂ᐱ 曐ᅤ ﱄﱈ㕐ϵĂ ㅌᒢﱐὣ¢ﰸ ﱄﯰ⁝¢ﱐﯼ¢ﱐﱘ↯¢ﱐ
-
08/08/2020
What kinds of systems are there for central air conditioning Which is better for home installation
What kinds of systems are there for central air conditioning Which is better for home installation For owners who want to decorate their new home, air conditioning may be an essential part of building a comfortable home.
-
06/29/2020
What is the cause of compressor pipeline vibration
-
09/18/2020
The advantages of Copeland compressors are as follows
Copeland compressor has a solid cast iron body, provides a large heat dissipation area to improve the cooling effect of air-conditioning compressors, and uses lightweight aluminum pistons to reduce friction and vibration. The intelligent electronic protection film block can provide comprehensive motor protection. Super high energy efficiency:
-
03/25/2022
How Does a Circuit Breaker Work?
Circuit breakers are an essential part of any electrical system. Circuit breakers protect homes from various electrical hazards (such as overloading) and cut off power if the current becomes unsafe.