Type | 3RV1 |
Breaker Type | Motor Protection Circuit Breakers |
Rated current | 0.2 |
Number of Poles | 1 pole |
Setting range for thermal overload releases | 0.14...0.2 A |
Suitable for induction motors with P | 0.06 kW |
Instantaneous overcurrent releases | 2.6 A |
Short-circuit breaking capacity | 100 kA |
Weight approx. | 0.246 kg |
Circuit breaker size S00 for motor protection, CLASS 10 A-release0.14...0.2 A
N-release 2.6 A Screw terminal Standard switchingcapacity with transverse auxiliary switch 1 NO+1 NC
product brand name SIRIUS
product designation Circuit breaker
design of the product For motor protection
product type designation 3RV1
General technical data
size of the circuit-breaker S00
size of contactor can be combined company-specific S00
product extension auxiliary switch Yes
power loss W for rated value of the current
at AC in hot operating state 5.5 W
at AC in hot operating state per pole 1.8 W
insulation voltage with degree of pollution 3 at ACrated value 690 V
surge voltage resistance rated value 6 kV
maximum permissible voltage for safe isolation
in networks with grounded star point betweenmain and auxiliary circuit400 V
protection class IP
on the front IP20 of the termina lIP00
mechanical service life (switching cycles)
of the main contacts typical 100 000
of auxiliary contacts typical 100 000
electrical endurance (switching cycles) typical 100 000
reference code acc. to DIN EN 81346-2 Q
Ambient conditions
installation altitude at height above sea level maximum 2 000 m
ambient temperature
during operation -20 - +60 degrees centigrade
during storage -50 -- +80 degrees centigrade
during transport -50 ... +80 degrees centigrade
temperature compensation -20 -- +60 degrees centigrade
relative humidity during operation10 - 95 %
Main circuit
number of poles for main current circuit 3
adjustable pick-up value current of the current-dependent overload release 0.14 - 0.2
Aoperating voltage
rated value 690 V at AC-3 rated value maximum 690 V
operating frequency rated value 50 -- 60 Hz
operating current rated value0.2 A
operating current
at AC-3 at 400 V rated value 0.2 A
operating power at AC-3
at 230 V rated value 25 W
at 400 V rated value60 W
at 500 V rated value60 W
at 690 V rated value90 W
operating frequency at AC-3 maximum 15 1/h
design of the auxiliary switcht ransverse
number of NC contacts for auxiliary contact 1 note 1
number of NO contacts for auxiliary contacts 1 note 1
number of CO contacts for auxiliary contacts 0
operating current of auxiliary contacts at AC-15
at 24 V 2 A at 110 V 2 A at 120 V 2 A at 125 V 2 A at 230 V 0.5 A
operating current of auxiliary contacts at DC-13
at 24 V 1 A at 60 V 0.15 A
Protective and monitoring functions
product function
ground fault detection No
phase failure detection Yes
trip class CLASS 10
design of the overload release thermal
operational short-circuit current breaking capacity(Ics) at AC
at 240 V rated value 100 kA
at 400 V rated value 100 kA
at 500 V rated value 100 kA
at 690 V rated value 100 kA
maximum short-circuit current breaking capacity (Icu)
at AC at 240 V rated value 100 kA
at AC at 400 V rated value 100 kA
at AC at 500 V rated value 100 kA
at AC at 690 V rated value 100 kA
response value current
of instantaneous short-circuit trip unit 2.6 A
UL CSA ratings
full-load current (FLA) for three-phase AC motor
at 480 V rated value0.2 A
at 600 V rated value0.2 A
contact rating of auxiliary contacts according to UL C300 R300
product function short circuit protection Yes
design of the short-circuit trip magnetic
design of the fuse link
for short-circuit protection of the auxiliary switchrequired
fuse gG: 10 A, miniature circuit breaker C 6 A (short-circuit currentIk less 400 A)
design of the fuse link for IT network for short-circuit protection of the main circuit
at 240 V none required
at 400 V None required
at 500 V None required
at 690 V None required
Installation mounting dimensions
mounting position any
mounting type screw and snap-on mounting onto 35 mm standard mounting railaccording to DIN EN 60715
height 90 mm width 45 mm depth 75 mm
Siemens Circuit Breaker 3RV1011-0BA15
People who bought this item also viewed
Siemens Circuit Breaker 3RV2023-4AA10
Siemens Circuit Breaker 3RV1021-1JA15
Siemens Circuit Breaker 3RV1011-0KA10
Siemens Circuit Breaker 3RV1021-0EA10
Siemens Circuit Breaker 3RV1041-4JA15
Siemens Circuit Breaker 3RV1011-0FA10
Siemens Circuit Breaker 3VA9257-0FK21
TRIAD Transformer MD-2000-U
Shilin Contactor S-P09 24V
Littelfuse Fuse FLM4
CELDUC Relay SC965160
UniOhm Resistor 201007J0393T4E
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder DGC-63-375-KF-PPV-A
Shinko Temperature Controller PCB1S00-40
SANYO Battery UR16650ZTA
Panasonic Servo Motor MQMF011L1C4
HYSEIKO Linear Guideway RM25FAL
Recent related posts
-
11/09/2021
PLC (Programmable Logic Controllers) and HMI (Human-Machine Interface) for Intelligent Factory
The development of "intelligent factory" has put forward a new direction for manufacturers. It is necessary for manufacturers to master the production and marketing process clearly
-
06/29/2020
Precautions for the use of screw air compressor oil
Precautions for the use of screw air compressor oil Note on the use of screw air compressor oil: It is forbidden to mix air compressor oils of different brands and grades. The old oil must be drained when replacing. It is strictly forbidden to add or filter and reuse.
-
11/06/2023
Should the Radiator Fan Turn On When the AC Is On?
When it comes to the operation of your vehicle's cooling system, the radiator fan plays a crucial role. It helps dissipate heat from the engine coolant, ensuring that the engine stays within its optimal temperature range.
-
08/11/2020
How to check the air tightness of refrigeration equipment correctly
The refrigeration equipment is kept under a proper vacuum for a certain period of time. Whether the reading of the vacuum pressure gauge changes to reflect and observe whether the air penetrates into the system to check the sealing performance of the system.
-
12/26/2022
What is a Programmable Logic Controller?
The programmable logic controller (PLC) is a digital operation electronic system specially designed for application in industrial environment.
-
07/26/2023
Heat Pump Makes Loud Noise When Turning Off: Causes and Solutions
A heat pump is an essential part of many homes, providing both heating and cooling to keep the indoor environment comfortable. Like any other appliance, it can sometimes develop issues that require attention. One common problem that homeowners may face is a heat pump making loud noise when turning off.
-
12/22/2022
How to Maintain Optical Fiber Amplifiers?
An optical fiber amplifier (OFA) can not only directly amplify optical signals, but also have the advantages of real-time, high gain, online, low noise and low loss.
-
10/24/2023
How Do Window AC Units Work: Basics, Working Principle, Installation and Maintenance
Window air conditioning units are popular choices for cooling individual rooms or small spaces. Understanding how these units work can help you make informed decisions about their installation and maintenance.
-
08/20/2020
Introduction of solenoid valve and troubleshooting method
1. Symptoms-the solenoid valve does not open possible reason: 1 The coil has no voltage. 2 Incorrect voltage/frequency 3 Coil burned out 4 Pressure
-
09/08/2020
What are the functions of the air compressor dewatering device
The compressed air produced by the compressor is not pure. This is because the air compressor itself contains lubricating oil. During the compression work, part of the lubricating oil must be mixed into the compressed air.