Schneider Soft Starter ATSU01N212LT
People who bought this item also viewed
Siemens Soft Starter 3RW3016-1CB14
Siemens Soft Starter 3RW4047-1BB14
Siemens Soft Starter 3RW3017-2BB04
ABB Soft Starter PSR6-600-70
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Yuci Vane Pump YYB-AB26-74B-DF-Y2
BRIDGE Welding Wire THS-310
AEROVOX Capacitor CP55BIFB106K
Recent related posts
-
06/27/2020
The working principle and characteristics of inverter compressor
Inverter compressor refers to a compressor whose relative speed is constant, and whose speed is continuously adjusted within a certain range through a control method or means, which can continuously change the output energy.
-
10/31/2021
Study on the Performance of Single Phase AC-DC-AC Inverter Circuit
Variable Frequency Drive(VFD) converts power in the motion control system. The motion control system now contains a variety of disciplines.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/01/2020
Several advantages of screw compressor
Several advantages of screw compressor In the cold storage installation, the choice of refrigerator is to choose to use screw machine or piston machine. The use of screw machines is gradually surpassing the share of the original piston machines.
-
06/14/2020
The difference between single and twin screw compressors is reflected in the following 6 aspects
The difference between single and twin screw compressors is reflected in the following 6 aspects
-
03/20/2023
Structural Characteristics of Vacuum Pump
The vacuum pump refers to a device or equipment that uses mechanical, physical, chemical or physical-chemical methods to extract air from the pumped container to obtain a vacuum.
-
11/25/2021
As 5G is on the Way, Do You Really Understand the Use of HMI?
What is HMI (Human Machine Interface)? This era is smart and full with information. We have already been placed in the age of smart technology and filled with all kinds of new devices and inventions every day.
-
03/01/2021
Advantages of hollow axis servo motor
The diameter of hollow shaft can reach 40mm Compact size IP65 protection level Low rotor moment of inertia, high dynamic response characteristics
-
06/05/2023
13 Reasons Why LG Refrigerator Not Cooling and Solutions (The Latest Version)
With the improvement of living standards, refrigerators have become an indispensable part of family life.
-
08/13/2020
Adjustment method of one machine multi-storage refrigeration system
In some cold storage, one refrigeration unit is used to supply cold storage to several cold storages with different temperature at the same time.