Pipe Size:PT3/8
Flow Aperture:7mm
Coil Voltage:DC24V
AirTac Solenoid Valve 2SL050-10-DC24V
People who bought this item also viewed
AirTac Solenoid Valve 4V410-15-DC24V
AirTac Solenoid Valve 4V430C-15B
AirTac Solenoid Valve 2V02508B
AirTac Solenoid Valve 2W150-15-DC24V
Daikin Solenoid Valve KSO-G03-2DP-30-EN
SUNX Sensor GX-M12B-P-Z
Danfoss Expansion Valve 067N3180
KOMPASS Check Valve MBA-02-H
ZHONGDA Electric Motor Z3D36-12GN
Jeou Gang Overflow Valve MRV-02-A-3-W
YUKEN Piston Pump A90-L-R-01-C-S-60
NVICKS Vane Pump 4535VQ66A35-1CC20R
Samsung Expansion Valve Coil 2.2C-05
Rubycon Capacitor PX 400V 33UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
LEEMIN Filter SFAX-400-5
TTO Oil Seal TB 36*55*6.5
HITACHI Capacitor 10V10UF
EPCOS Capacitor 420V 82UF
Togami Contactor CLK-150H
Recent related posts
-
08/30/2023
Heat Pump vs Conventional HVAC: Which is Better for Your Home?
When it comes to heating and cooling your home, there are two main options: heat pumps and conventional furnace and AC systems. In this article, we'll take a closer look at heat pumps and conventional furnace and AC systems
-
06/10/2022
How To Replace A Solenoid Valve Coil?
The solenoid valve coil generates a magnetic field. This moves a ferromagnetic plunger inside the valve which opens or closes the valve. When a coil (solenoid) is defective, it can be difficult to find a replacement for the original.
-
07/10/2020
What is the working principle of screw air compressor
What is the working principle of screw air compressor The screw-type single-stage compression air compressor is composed of a pair of yin and yang rotors (or screws) that are parallel to each other and rotate in the cylinder, so that the air between the rotor slots continuously produces periodic volume changes,
-
03/06/2023
Types of Cylinder Seals and Factors Affecting Sealing Performance
Cylinder sealing is an important parameter to characterize the technical condition of engine. Cylinder sealing is related to the technical condition of cylinder block, cylinder head, cylinder gasket, piston, piston ring, inlet and exhaust valves and other parts.
-
08/20/2020
What is an air conditioner pressure sensor
The pressure sensor is a device that is installed on the pipeline of the outdoor unit of the air conditioner to perform pressure detection. The pressure detection result is transmitted to the computer board to control other parts of the air conditioner.
-
08/23/2020
Why is it forbidden to use the refrigerator
We all know that with the continuous improvement of people’s material living standards, every household now has a refrigerator. The refrigerator is very useful in the home, especially in summer.
-
08/13/2020
How to replace the lubricating oil and filter drier of the chiller
After the chiller is used for a long time, the lubricating oil will inevitably be contaminated or acidified. Therefore, we must pay attention to the change of oil quality during the operation of the unit.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
11/17/2021
Why Commercial Ice Maker not Work and Solutions
In modern city life, it's easy to see ice makers in restaurants, supermarkets, bars, cafes and other places, and there are car ice makers too.
-
07/19/2020
Why does the scroll refrigeration compressor reverse? What about reversal?
We know that the operation of the internal compression structure of the refrigeration compressor has a fixed direction. First of all, we need to make it clear: the occurrence of reverse rotation must be unfavorable for the refrigeration compressor.