Port size:Rc(PT)3/8, Rc(PT)1/2, Rc(PT)3/4
Operating pressure range (MPa):0.15-1.0
Maximum working frequency:3 c/sec
Manual override:Push button non-locking (standard),lever locking (option)
Coil insulation class:Class F or equivalent
Power consumption:AC:Holding 5.5 VA (50/60 Hz),DC:2.5 W
ARK Solenoid Valve KVF7140-DC24V
People who bought this item also viewed
ARK Solenoid Valve KVF3130-DC24V
MAC Solenoid Valve 180001-112-0021
KOGANEI Solenoid Valve 380-4E1-PSL
Daikin Solenoid Valve C-KSO-G02-20BB-30
Huba Control Transmitter 699.B12025144
Elco Sensor NI50-W80-BP6L-Q12
SMC Proportional Valve ITV2031-31N2L4
KITZ Check Valve UO-DN25
DKM Electric Motor 9IDGC-200F2WH
TOP Overflow Valve MRV-03A
DUPLOMATIC Gear Pump GP30394R95F20N
Donaldson Filter X011926
Danfoss Sight Glass SG6S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KUDOM Relay KMTYM380D15-24N
SUNX Sensor SS-D20
Banner Sensor QS12VP6DBZ
AirTAC Air Cylinder MF20X125-S
Recent related posts
-
06/20/2020
The role of condensing pressure regulating valve
Condensing pressure regulating valve When the refrigeration device is running, if the condensing pressure is high, the compressor discharge temperature will rise; the compression ratio will increase; the cooling capacity will decrease; The higher the condensing pressure, the greater the above adverse effects. The high condensation pressure is mainly seen in summer. <img src="{{media url="The_role_of_condensing_pressure_regulating_valve.jpg"}}" alt="" />
-
12/21/2021
How to Calibrate a Pressure Transmitter Before Use
Pressure transmitter is a kind of commonly used measuring instrument, which can convert the physical parameters such as gas and liquid sensed by load cell into standard signal output.
-
06/13/2020
Refrigeration unit in artificial environment simulation laboratory
The artificial environment simulation laboratory can simulate the temperature and humidity environment, as well as the climatic environment of rainfall, snowfall, sunshine, wind, sand and dust.
-
07/17/2020
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit
Cause Analysis and Treatment Method of Copper Tube Leakage of Evaporator of Single Cooling Unit A central air-conditioning system in a public area uses a screw chiller. During operation, a copper tube in the evaporator leaks due to a malfunction. After further inspection by the technical staff, it was confirmed that the fault was leakage of the copper pipe of the evaporator of the chiller.
-
08/17/2020
Precautions for the safe use of chillers
In order to ensure the safe operation of the chiller and protect the personal safety of the staff, the operator must be familiar with the knowledge of the safety management of the chiller. Please read it carefully before using the chiller.
-
08/17/2020
What is the principle of the chiller shell and tube evaporator
The cold water shell and tube evaporator is made by expanding two-layer metal plates with high-pressure gas or by mechanical pressing. It can also be made of aluminum alloy die-casting.
-
05/30/2023
Why Does My AC Compressor Turn on and off Repeatedly?
Under the control of the thermostat, generally the air conditioner will stop working when it reaches the set temperature. For example, when the indoor temperature is 35 °C, you turn on the air conditioner and set it to cooling mode
-
06/13/2020
Compressor common knowledge, how much do you know
Compressor common knowledge, how much do you know The compressor is the heart of the refrigeration system. It sucks low-temperature and low-pressure refrigerant gas from the suction pipe, drives the piston to compress it through the operation of the moto 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿
-
06/30/2020
You should know the normal working condition of the compressor in the cold storage
You should know the normal working condition of the compressor in the cold storage 1. The suction temperature of the compressor should be 5-15℃ higher than the evaporation temperature.
-
09/06/2021
Why is Your Car AC Starting and Stopping Frequently?
Many car owners are puzzled to find their air conditioners starting frequently while driving. In fact, the normal start and stop period of the air conditioner