ASHUN Solenoid Valve AHD-G02-2A3-AC110V-20
Type: Solenoid Valve
Brand: ASHUN
Valve size: 1/4"
Power source: AC110V
Type of connection: Din type
Piping way: SUB-PLATED TYPE
Type: Solenoid Valve
Brand: ASHUN
Type: Solenoid Valve
Brand: ASHUN
Honeywell Solenoid Valve VE4020B1145T
MAC Solenoid Valve 166B-611JB
MAC Solenoid Valve 167B-121JB
Danfoss Compressor HLY55AAa
Meas Transmitter M5156-C2547U-040BG
CHINT Transformer BKC-150
Bellofram Proportional Valve 961-078-000
Delixi Contactor CJX2SF-115
V.T.V Electric Motor V.T.V-07
Rexroth Piston Pump A4VSO71EO1/30R-VPB13N00
HENGYI Vane Pump VP5F-A4-50
HYTEK Gear Pump HG21-80-160-01R-VPC
DAIKIN Expansion Valve Coil R71DQY3C
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
RIKEN Light Curtain RPZ425-180X2
Honeywell Sensor HIH-3610-001
DHF Tool for Metal Cutting UET0304S
Pilz Relay 774042
MTL Encoder MEH-30-3600PE
VTOZ Overflow Valve WDKQ-023-C-P24DC
08/08/2022
Synchronous motors like induction motors (i.e. asynchronous motors), are a common type of AC motor.
07/20/2022
When installing a pneumatic diaphragm pump, anyone who is not familiar with pumps and pump installations will often make small mistakes that result in costly damages.
09/08/2020
There are many setting parameters of the air compressor inverter, and each parameter has a certain adjustment range. In the application, it is often encountered that the air compressor inverter cannot operate normally due to the improper setting of a single parameter. Therefore, it is necessary to Make accurate settings for the relevant parameters.
08/11/2020
The electrical installation of cold storage engineering can include overhead lines, lighting, cables, machine room wiring, workshop or factory area power transformation and distribution.
08/14/2020
In the evaporator, the heat of the cooled medium is transferred to the refrigerant through the heat transfer wall, so that the liquid refrigerant absorbs heat and vaporizes.
06/14/2020
This summer, the air-conditioning market is popular with sterilization, fresh air or a new engine for growth The winter air-conditioning market in 2019 ended with a price war, and then the new crown epidemic hit the offline market again.
06/27/2020
The sign of the normal operation of the refrigeration unit 1. There is no knocking sound in the piston refrigeration compressor, the compressor is operating normally, the expansion valve opening is adjusted properly, and there is only compressor suction and exhaust sound during operation, and no knocking or other abnormal sounds are produced.
08/15/2020
In the process of maintenance of the refrigerator, if there is a fault in the system components from the compressor exhaust shut-off valve to the accumulator outlet valve
08/02/2020
don’t know if you still remember that okmarts.com wrote "How to Choose Refrigerant for Cold Storage Design" some time ago. Today okmarts.com will introduce several different cold storage refrigerants in detail, namely R12, R22, R407C
01/16/2022
The piezoelectric pressure transducer, a measuring precision instrument, mainly works with the piezoelectric effect that is the use of electrical components