Nominal Diameter: 10 mm < br > Control mode: normally open unloading < br > Input voltage: DC24V < br > Installation type: plate installation < br >
NORTHMAN Solenoid Valve HSRF-G03-1PN-3-L-D24-10-30
People who bought this item also viewed
CKD Solenoid Valve 4SB019-C3
CKD Solenoid Valve FS2-03-4-AC220V
CHELIC Solenoid Valve SV-310-K
Honeywell Solenoid Valve VE4015A1070
CKD Solenoid Valve 4GB119-E2-DC24V
GMCC Compressor PA150M2AS-3KTM1
Endress Hauser Transmitter FMX167-A1AMC1A7
Banner Sensor T18-2NAES-2M
Siemens Contactor 3RT1266-6AR36
ASLONG Electric Motor JGY-370B
ARON Overflow Valve ADP503
CAT Piston Pump 4SF35GS1
HENGYI Vane Pump PV2R23-41-116-F-REAA-41
YORK Expansion Valve Coil D22FKS-2R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SMC Solenoid Valve SYJ3140-5LOU-Q
SOG Oil Seal TB38*65*10
DHF Tool for Metal Cutting UNB0503
Recent related posts
-
06/29/2020
Analysis of the cause of excessive suction temperature of compressor
Analysis of the cause of excessive suction temperature of compressor The high suction temperature is mainly due to the increase of superheat of suction. Note that high suction temperature does not mean high suction pressure, because the suction is superheated steam. Under normal circumstances, the compressor cylinder head should be half cold and half hot. If the suction temperature is too high, the cylinder head will all heat up.
-
01/15/2021
Dafoss high-pressure
High pressure Compressor Compressor discharge pipe too hot Probable bellows leak in KVC capacity regulator. Solution Slowly loosen protective cap. If pressure or traces of refrigerant exist under the cap,there is a leak in the bellows.Replace val
-
07/31/2020
Principle analysis of monitoring system for cold and heat source equipment
The building automation system is an integrated system platform, in which many subsystems have diverse functions and complex engineering. What is the principle of the cold and heat source equipment monitoring system as one of the many subsystems of the building automation system?
-
01/12/2021
Recommend that you use Mitsubishi Electric Air Conditioner
Recommend that you use Mitsubishi Electric Air Conditioner Recently, many businesses recommend Mitsubishi Electric air conditioners, Emphasized the keel motor; Let me introduce you today: Where is the keel motor? Mitsubishi Electric patent: [ 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب
-
09/14/2020
Air compressor
KESO Industrial Group is the world’s leading industrial air compressor equipment manufacturer. Headquartered in Minnesota, in the north-central United States, Shanghai Keso Compressor Co., Ltd.
-
06/13/2020
How about ultra-small refrigeration compressors Features introduction of ultra-small refrigeration compressors
Among the components of our refrigeration compressor, the compressor is very important, and an ultra-small refrigeration compressor is widely used in our equipment with a refrigeration capacity of less than 1KW, so today I will introduce you to us Some of 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜
-
06/20/2020
Common failure and analysis of centrifugal air compressor
Common failure and analysis of centrifugal air compressor 1. Abnormal vibration and noise: ① Misalignment ② The compressor rotor is unbalanced ③ The impeller is damaged ④ The bearing is abnormal ⑤ The coupling is faulty or unbalanced ⑥ The sealing ring is bad ⑦ The oil pressure and oil temperature are abnormal ⑧ There is dirt in the oil Clean, wear out the bearing ⑨ Surge ⑩ The stress of the gas pipeline is transmitted to the casing, which causes misalignment ⑪ There is a machine working near the compressor<img src="{{media url="Common_failure_and_analysis_of_centrifugal_air_compressor.jpg"}}" alt="" />
-
06/24/2020
Why the air conditioner does not cool
The cooling load is overloaded or the space is too large, the number of air conditioners is not correct; improper installation will cause poor air circulation, resulting in poor cooling effect; when the freon in the air conditioner is insufficient, it will cause the cooling effect of the air conditioner to deteriorate; the air conditioner is not on time Do cleaning and maintenance, etc.
-
08/14/2020
The layout principle of Freon refrigerant pipeline
The main feature of Freon refrigerant is that it dissolves with the lubricating oil. Therefore, it must be ensured that the lubricating oil from each refrigeration compressor can return to the refrigeration compressor after passing through the condenser,
-
07/15/2020
What you need to know about the electrical connection of Copeland refrigeration compressors
Please pay attention to the direction of the terminals in the junction box (single-phase: R, S, C; three-phase: T1, T2, T3). In order to ensure the normal start-up and operation of the Copeland refrigeration compressor, the power supply voltage cannot be lower than 10% of the Copeland compressor rated voltage.