There is no price at present, you can Request a Quote
Working pressure (bar): 0.2 Max.
Temperature -20degs -+ 60degs
Voltage: 230V 50Hz
WATTS giuliani anello Solenoid Valve GSAV25R
There is no price at present, you can Request a Quote
People who bought this item also viewed
AirTac Solenoid Valve 4V110M5BI
Honeywell Solenoid Valve V4043C1362
CHINT Transformer JBK1-630
Parker Sporlan Expansion Valve FSE-1-Z
Nass Solenoid Coil 108-030-0272
DANFOSS Check Valve NRVH19S
7OCEAN Overflow Valve S-DB-30-1-10
TOKIMEC Piston Pump P130V-FRS-11-CMC-10-J
YI-SHING Vane Pump 150T-116-FR-PA
Danfoss Sight Glass SGP6SN
DAIKIN Expansion Valve Coil DM-89R
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HIWIN Linear Guideway HGW55CAZAC
COKERY Belt 327J
IFM Sensor OF5024
Festo Sensor SPAB-P10R-N18-2N-L1
IFM Sensor PI2789
Recent related posts
-
11/17/2021
Which is Best - Comparison of KingView SCADA Software and HMI Touch Screen Control
HMI touch screen, also known as "touch panel", is an inductive liquid crystal display device that can receive input signals such as contacts.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
11/17/2022
What is an Axial Fan Used for?
As for an axial fan, the air flows parallel to the axis of the fan. It has a wide range of uses, such as electric fans, outdoor fans of air conditioners.
-
08/20/2020
Solution to condensation on air outlet of air conditioner
Part 1: Causes of condensation at the air outlet 1. Theoretical analysis of condensation: First of all, we must first understand the cause of condensation and why it occurs.
-
08/02/2020
Refrigerator refrigeration system leak detection
The refrigeration system should be tested for leaks due to refrigerant leakage or refrigerators after replacing parts. The following three methods are generally used for leak detection in refrigeration systems
-
06/13/2020
The reason for the failure of the multi-line air-conditioning compressor is revealed!
The reason for the failure of the multi-line air-conditioning compressor is revealed! 1 Overview The failure of motor compressor (hereinafter referred to as compressor) can be divided into motor failure and mechanical failure (including crankshaft, co 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ
-
06/13/2020
Working principle of inverter compressor
The principle of inverter compressor inverter controller is to convert the alternating current in the power grid into a square wave pulse output. By adjusting the frequency of the square wave pulse (that is, adjusting the duty cycle), the speed of th ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ
-
01/15/2021
Operation process of automobile air-conditioning refrigeration system and the role of pressure switch
Operation process of automobile air-conditioning refrigeration system and the role of pressure switch From top to bottom, automobile air conditioners are mainly composed of blowers, evaporators, pressure switches, dryers, expansion valves, condensers, 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐
-
09/18/2020
Jingliang Electronics-Air Compressor Sensor Solution
——High-quality, cost-effective to provide customers with perfect sensor solutions Precision Electronics-MEAS (MSI) Sensor Co., Ltd. is a precision electronic engineering expert who masters the world's leading silicon micromachining MEMS technology.
-
11/06/2022
What is an Electronic Expansion Valve?
The electronic expansion valve is a kind of the expansion valve. It uses the electrical signal generated by the adjusted parameters to control the voltage or current applied to the expansion valve, thereby achieving the purpose of adjusting the liquid supply.