There is no price at present, you can Request a Quote
Fluid: air
Operation ambient temperature range: -10 - 60 degree celsuis
Bore size: 80mm
Stroke: 80mm
Adjust stroke: 25mm
STNC Air Cylinder TGUJ-80X80-25-TC
There is no price at present, you can Request a Quote
People who bought this item also viewed
AirTAC Air Cylinder SC40X70
Festo Air Cylinder EG-6-15-PK-3
MINDMAN Air Cylinder MSBS-32-20
Festo Air Cylinder SLT-25-150-A-CC-B
CKD Air Cylinder SSD2-L-12-5-N-W1
Festo Solenoid Valve CPE18-M3H-3OL-1/4
SIEMENS Actuator SAL61.03T10
SMC Proportional Valve ITV3050-223L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
KOINO Switch KH-7011
UNIVER Solenoid Valve BE-5930
SHENYU Vane Pump HVP-30-140
SANGEE Fan SW350HA1
PIZZATO Switch FZ 1001-M2
Recent related posts
-
07/16/2020
Vacuum leak test method for small cold storage equipment
Refrigeration systems with evaporating pressure gauges close to or below atmospheric pressure must be tested for vacuum leak tests, leaving the refrigeration equipment under proper vacuum for a certain period of time, reflecting and observing whether air has penetrated into the system from the reading of the vacuum pressure gauge for inspection The sealing performance of the cold storage equipment system.
-
06/14/2020
How to distinguish original refrigeration compressors from second-hand compressors
How to distinguish original refrigeration compressors from second-hand compressors How to distinguish the original refrigeration compressor from the second-hand refrigeration compressor? In fact, this is the same as the RMB identification method, and it 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔
-
08/11/2020
The load calculation formula of computer room air conditioner
The load calculation formula of computer room air conditioner<br></br> How to obtain heat and cooling load in the computer room and how to calculate the cooling capacity required in the constant temperature and humidity room.
-
07/25/2020
This is the "3 times", "8 steps" and "5 keys" of central air conditioning installation~~
It is not an exaggeration to say that the central air conditioner is installed with 3 points and 7 points for quality. The central air conditioner needs to be properly matched with the interior decoration. In fact, the equipment itself is only a "semi-finished product".
-
08/15/2020
Reasons for the large difference in cooling of different refrigeration equipment
According to the analysis of the use environment, due to the differences in the cooling methods of the refrigeration equipment, enterprises need to carefully analyze the particularity of the use
-
12/29/2022
Advantages and Disadvantages of the PLC
The programmable logic controller (PLC) is a digital operating electronic system specially designed for application in industrial environment.
-
06/20/2020
Installation instructions for explosion-proof air conditioners
Installation instructions for explosion-proof air conditioners <img src="{{media url="Installation_instructions_for_explosion-proof_air_conditioners.jpg"}}" alt="" /> 1. The power supply of the explosion-proof air conditioner shall have a dedicated line, and a circuit breaker or air switch shall be provided in the dedicated line. The power supply wires and fuses should comply with the relevant regulations and cannot be changed at will.
-
09/28/2023
Water Chiller for Ice Bath Explained: Working Principle, Pros and Cons, Application
Ice baths have been used for centuries as a form of therapy to reduce inflammation, relieve pain, and improve recovery time. Ice baths work by constricting blood vessels, which reduces blood flow and inflammation in the affected area.
-
06/14/2020
Nine refrigerant leakage parts and solutions
There are many welding ports on the left and right sides of the evaporator, and there may be more leakage points. The leakage of the newly installed air conditioner is mainly due to the poor welding technology of the employees of the air conditioner prod 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž
-
06/23/2020
What is the solution of air conditioning not cooling
There are many reasons why the air conditioner is not cooling. For example, if the air conditioner refrigerant is insufficient, you can find a professional to add snow; secondly, it may be caused by the error of the air conditioner installation, such as the ventilation pipe is too long. It is recommended to shorten the length of the ventilation pipe; A lot of dust stains accumulate on the radiator and cause no cooling. It is recommended to clean the air conditioner.