There is no price at present, you can Request a Quote
Fan Type | DC Fan |
Series | M Series |
Voltage | 5 VDC |
Frame Size | 30 mm |
Frame Thickness | 15 mm |
Frame Material | - |
Bearing Type | Vapo |
Speed | High |
Function | AutoRestart and F type(3rd wire) |
Size | 30 mm x 30 mm x 15 mm |
Power Current | 140 mA |
Power Consumption (WATTS) | 0.7 W |
Speed | 9500 RPM |
Air Flow | 6 CFM |
Static Pressure | 0.17 in H2O |
Noise | 27dB(A) |
Termination | - |
IP Rating | - |
Approval Agency | - |
Operating Temperature | - |
Weight | - |
We can also provide the following models
MF35100V1-0000-G99
PMB1203ALB1-A
ME80151S2-0000-Q99
GB4812AHV2-A
PE60252B1-0000-Q99
PMD4855PNB1-A
PMB0506AMV3-AY
PMB1201ATB2-A
HA40200S2-0000-C99
MF60150S2-10000-Q99
EF40201V2-10000-F99
EE80251V3-0000-G99
PMD1209PWB4-A
MF20081S3-0000-Q99
EE80154S4-10000-G99
GB0597AOVX-AY
MB45100V4-10000-999
MF40201S3-0000-Q99
MF25152B3-10000-F99
PMB0503ATV4-A
EF60201S1-10000-Q99
GB0555PGV2-AY
GB4807AMV1-A
GB4801AGB2-A
MB45101B2-10000-999
VF60380S4-0000-F99
PMB1275AEB1-A
PMB0555AWV2-A
PMB2438ADBX-AY
PF75300V3-1B000-999
PMB1245AIB2-AY
MF60102V2-0000-F99
GB1204AKB2-A
PFE0384V4-0000-G99
AB1095-MVT
SF23092A 1122MST.GN
EF80251B4-10000-G99
SF11580AT 1122MSL.GN
GB2435PMB3-AY
GB4803AIV1-A
PMB2455POBX-A
PMB4855AWB1-AY
PMD1238AEB2-A
PMD24H0ADVX-A
SP101A 1083MBT.GN
MEC0251B3-0000-Q99
MF50201V4-B000-S99
HA40101B3-0000-A99
PF92254B2-0000-F99
MF60204V2-10000-F99
PMB1207PIB1-A
For more information,please contact us freely
SUNON Fan MF30150V1-10000-G99
There is no price at present, you can Request a Quote
People who bought this item also viewed
Ebmpapst Fan S2E250-BE65-01
SUNON Fan MF75090V1-C160-G99
SUNON Fan DP203A 2123LSL.GN
SUNON Fan PMD4807PTB1-A
SUNON Fan EEC0252B1-000U-G99
SUNON Fan DP202A 2123MSL.GN
Sanyo Denki Fan 9BMB12P2G01
Delta Fan NS85B01-17A02
SUNON Fan SF11580A 1083HBL.GN
Bristol Compressor H2EB223ABK
Weidmuller Power Supply 8951350000
TRIAD Transformer CSE187L
Siemens Circuit Breaker 5SJ6350-7CR
TENGEN Contactor CJ20-63A 380V
TAISEI Filter SFT-24-100W
Danfoss Sight Glass SGP22SN
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PROCON Water Pump 10643
Sanyo Denki Fan 9S1212F402
VTOOL Tool for Metal Cutting 11.20mm
KYB Hydraulic Motor MAG-50VP-800
Omron Sensor E2E-X2MF1
Recent related posts
-
06/13/2020
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
Home air conditioning is not cooling, still looking for someone to repair at a high price Here teach you how to repair!
-
07/27/2020
Principles and advantages and disadvantages of screw refrigeration compressors in cold storage
Principles and advantages and disadvantages of screw refrigeration compressors in cold storage Foreword: The cold storage house detailed the classification of cold storage compressors in the article "Introduction to the types of cold storage refrigeration compressors". Among them, screw compressors are mentioned.
-
01/12/2023
What is a 3/2 Solenoid Valve?
A solenoid valve is an electro-mechanical valve that is commonly employed to control the flow of liquid or gas.
-
08/15/2020
The correct operation method of air-cooled refrigerator
For companies that use air-cooled refrigerators, the stable use of equipment is the most important thing, and if you don’t pay much attention during use, it will cause problems with the stability of the equipment due to some external factors.
-
09/18/2020
List of foreign medium and high pressure compressors in the Chinese market
When it comes to high-pressure compressors, they are not commonly used air compressors. They are widely used in pressure testing, chemical, bottle blowing, engineering, energy, electric power, military, medical and other industries. The general batch is relatively small, and domestic I think the high-pressure machine market is still in a budding state, and there is no more good capital and technical force to invest in this aspect of production;
-
08/20/2020
How much is the temperature of the industrial chiller to prevent condensation
Condensation water in the industry is mainly caused by the large temperature difference between the ambient temperature and the cooling water temperature of the chiller.
-
06/13/2020
Thermal expansion valve
Thermal expansion valve Thermal expansion valves are commonly used in Freon refrigeration systems. Through the function of the temperature sensing mechanism, they automatically change with the temperature change of the refrigerant at the outlet of the ev 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ
-
06/13/2020
The reason for the failure of the multi-line air-conditioning compressor is revealed!
The reason for the failure of the multi-line air-conditioning compressor is revealed! 1 Overview The failure of motor compressor (hereinafter referred to as compressor) can be divided into motor failure and mechanical failure (including crankshaft, co 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ
-
08/15/2020
How to correctly remove the ammonia refrigerant when repairing refrigeration parts
In the process of maintenance of the refrigerator, if there is a fault in the system components from the compressor exhaust shut-off valve to the accumulator outlet valve
-
08/08/2020
How to add R410A refrigerant
How to add R410A refrigerant The pressure of R410A is about 1.6 times higher than that of R22 refrigerant. Therefore, in the process of construction and after-sales service, if there is an incorrect operation, a major accident may occur.