Extra-Large digital display
Auto-Tuning, Self-Tuning provided as standard
Full Multi-Input (Thermocouple, RTD, voltage or current)
High-speed control cycle of 50ms
Scaling Range of -19999 to 19999
Multi- Output (Selective)
4 Alarm Output
RS-232C,RS- 422A (RS-485) Communication Interface
Easy Replace from EC5800A
Full Multi-Input (Thermocouple, RTD,Voltage or Current)
Auto-Tuning, Self-Tuning Providedas Standard
Scaling Range: -1999 to 9999
Multi-Output (Selective)
4 Alarm Output
RS-232C, RS-422A (RS-485)
Communication Interface
Easy Replace to EC5500S
Full Multi-Input (Thermocouple, RTD,
Voltage or Current)
Auto-Tuning, Self-Tuning Provided
as Standard
Scaling Range: -1999 to 9999
Multi-Output (Selective)
4 Alarm Output
RS-232C, RS-422A (RS-485)
Communication Interface
Easy Replace to EC5500S
Power Supply Voltage 100 to 240V AC, 50/60 Hz
Power Consumption Less than 10 VA
Memory Element EEPROM
Input of Sensor Thermocouple, R.T.D./0-5V, 1-5V, 4-20mA
(Changeable by key)
Control Output Relay contact/SSR drive voltage/Current 4-20mADC
Control Method Two kinds of PID, ON/OFF
Operation Environment 0 to 50℃, 20 to 90%RH(Avoid making dew)
Storage Environment -25 to 70℃, 5 to 95%RH(Avoid making dew)
Extra-Large digital display
Auto-Tuning, Self-Tuning provided as standard
Full Multi-Input (Thermocouple, RTD, voltage or current)
High-speed control cycle of 50ms
Scaling Range of -19999 to 19999
Multi- Output (Selective)
4 Alarm Output
RS-232C,RS- 422A (RS-485) Communication
Human friendly display and operability
LCD (wide temperature range product) display of 16-character and 4-line
Graphic display of program pattern
Superb operability by comments display
Simultaneous display of process variable, set point, residual time and other related data
It is lineup about one channel type and two channel
types
1 channel-type basic model : EC5900R
2 channel-type basic model : EC5950R
The program function of fullness
The mass program of a maximum of 400 steps and 19patterns
DO : A maximum of 15 points, DI : A maximum of 12 points
Time Units : Enables to switch time unit (minute/second) of programsIt is easy edit about a program pattern by deletion/insertion function of a step, and deletion/copy function of a pattern
High accuracy : ± (0.1% + 1 digit)
Multi-Input (Thermocouple, RTD, Voltage or Current),
Multi-Output (Current, SSR drive, Relay)
Anti-overshoot control
Multi-PID, Programmed PID, Multi-output limit, Programmed output limit
Easy replace from EC5600S/EC5900A (They are following and terminal-arrangements community about a function and operability)