Phaseo Optimum
product or component type
Safety and isolation transformer
rated power in VA
63 VA
input voltage
230 V AC single phase, terminal(s): N-L1
400 V AC phase to phase, terminal(s): L1-L2
output voltage
115 V AC
secondary winding
Single
protective cover
Without
ambient air temperature for operation
-20...50 Celsius degrees
Complementary input voltage limits
207...253 V
360...440 V
network frequency limits
47...63 Hz
input voltage tolerance
+/- 15 V
efficiency
84 %
power dissipation in W
12 W
output sustained overvoltage
9 % (no load, hot state)
voltage drop at rated load
<= 0.1 %
no load losses
5.3 W
short-circuit voltage
0,0792
output protection type
Against overload, protection technology: external
Against overvoltage, protection technology: external
Against short-circuits, protection technology: external
connections - terminals
Screw type terminals for input connection, connection capacity: 5 x 4 mm^2 AWG 11
Screw type terminals for input ground connection, connection capacity: 1 x 4 mm^2 AWG 11
Screw type terminals for output connection, connection capacity: 2 x 4 mm^2 AWG 11
marking
CE
fixing mode
By clips (with mounting plate) on 35 mm symmetrical DIN rail
By 4 screws, screw(s) D= 4.8 mm on horizontal panel with derating to 90 %
By 4 screws, screw(s) D= 4.8 mm on vertical panel, operating position: horizontal
By 4 screws, screw(s) D= 4.8 mm on vertical panel, operating position: vertical
operating altitude
3000 m
electrical insulation class
Class B
width
78 mm
height
90 mm
depth
80 mm
product weight
1.6 kg
Environment product certifications
UR
EAC
standards
UL 506
IP degree of protection
IP20
environmental characteristic
EMC conforming to EN 62041
Safety conforming to EN 61558-1
Safety conforming to EN 61558-2-6
protective treatment
TC
ambient air temperature for storage
-40...80 Celsius degrees
overvoltage category
Class I conforming to VDE 0106-1
dielectric strength
Between winding and ground
Between primary and secondary
Schneider Transformer ABL6TS06G
People who bought this item also viewed
CHINT Transformer NDK(BK)-500
CHINT Transformer BKC-150
Schneider Circuit Breaker A9F18632
CHINT Contactor NXC-22
Delixi Fuse RT16-3 630A
PUNA Relay AH3-B
EBG Resistor MXP-35-10KR
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
IFM Sensor IFS297
DEHN Surge Protection Device DV M TNS 255 FM
SHAKO Air Cylinder TCB40C1000
COSEL Power Supply LFA150F-12-CJ1R
AirTAC Air Cylinder SEJ50X150-20S
CKD Air Cylinder FCD-L-40-50-N
Recent related posts
-
08/11/2022
What is Permanent Magnet Synchronous Electric Motor?
Permanent magnet synchronous motor (PMSM) is a synchronous motor that uses permanent magnets to establish an excitation magnetic field.
-
01/18/2022
Transmitter Common Faults & Diagnosis Methods
Transmitter faults mainly include complete fault, bias fault, shifting fault, and precision degradation fault. This is shown in figure 2.
-
08/15/2020
How to achieve low-cost operation of the freezer
Enterprise users who use refrigerators are more concerned about the cost of use. The editor of okmarts.com believes that only by saving energy can the cost of enterprise use be effectively saved.
-
10/23/2023
Air Conditioner Line Frozen: Causes, Troubleshooting and Prevention Methods
When the air conditioner line freezes, it can be a frustrating experience for homeowners. Not only does it disrupt the cooling process, but it also indicates an underlying issue that needs to be addressed.
-
08/16/2020
What factors will cause the cooling performance of water-cooled chillers to decline
Water-cooled chillers are especially suitable for places with abundant water resources. The operation is more stable. It has the characteristics of large single-unit cooling capacity and high cooling efficiency.
-
07/28/2023
Heat Pump Making Loud Noise in Cold Weather: Causes and Solutions
When the temperature drops outside, your heat pump becomes an essential part of your home's heating system. While it's common for heat pumps to make some noise during operation, loud or unusual noises can be a cause for concern.
-
06/14/2020
Compressor
Compressor: It is the heart of refrigeration and heating cycles.
-
07/10/2022
How to Replace Mechanical Seals in Centrifugal Pumps
Mechanical seals are used in centrifugal pumps to keep water or any liquid from making contact with the delicate parts of the machine.
-
08/20/2020
The difference between chilled water, cooling water and condensed water and the principle of refrigeration
The central air-conditioning host is composed of a compressor, an evaporator, a condenser, and a throttle valve. The compressor provides energy. The condenser reduces the temperature of the refrigerant from the compressor.
-
07/24/2022
4 Common Causes of Water Pump
Most people know that a water pump is important to vehicle operation, but not everyone knows the four most common causes of water pump failure.