CEWE Transmitter DI122
People who bought this item also viewed
CEWE Transmitter DP125
CEWE Transmitter DP235
CEWE Transmitter DU125
CEWE Transmitter DQ235
Danfoss Transmitter 060G593705
SAND Transmitter PT111B-M14-50MPa
Adli Transmitter 4008.180.001
HORIBA Conductivity Meter DS-72E
OMEGA Pressure Gauge DPG210-300A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Dwyer Flowmeter RSF125
Siba Fuse 7006565 25A
HPC Piston Pump PP70-A1-F-R-2B+P08-A1-S
YUKEN Vane Pump PV2R12-19-26-F-RAAA-4222
Vickers Solenoid Valve SV3-12-0-0-12DG
Fuji Servo Drive RYC751D3-VVT2
Recent related posts
-
09/22/2020
Compressed air dewatering, oil removal and dust removal multifunctional filter
Compressed air degreasing, water removal and dust removal filter (purification equipment) Sometimes, connecting a piece of equipment to a compressed air supply station cannot solve the quality of compressed air.
-
09/08/2020
The characteristics of the main shaft of the frequency conversion screw air compressor
The main core of the equipment operation of the rod host during the operation of the variable frequency screw air compressor. Without the rod host equipment, the equipment cannot operate normally. The following is an explanation of the characteristics of the rod host used in the air compressor equipment:
-
06/14/2020
What is the role of refrigeration compressor in refrigeration system?
What is the role of refrigeration compressor in refrigeration system? The simplest and most popular explanation is that the refrigeration system uses the phenomenon that the refrigerant evaporates and condenses at different pressures to achieve refrigera 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱
-
03/12/2021
Composition of servo drive system
The controller is usually a computer or PID control circuit, and its main task is to transform and process the deviation signal output by the comparison element, so as to control the executive element to act as required.
-
08/14/2020
The reason why the fan of air-cooled chiller does not run
In many areas where water sources are lacking, or air-cooled chillers for cooling and cooling of supporting machinery and equipment, after several years of use, such and other small failures may occur.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/14/2020
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass"
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass" The energy regulation of the system is generally composed of the following ways: Compressor parallel-multi-stage contro 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
09/09/2020
The working principle of the oil filter
During the working process of the engine, metal wear debris, dust, carbon deposits and colloidal deposits oxidized at high temperature, water, etc. are constantly mixed into the lubricating oil.
-
08/13/2020
Four types of safety protection measures for refrigeration compressors
As the most important component of the chiller, the motor for the refrigeration compressor plays an important role in the after-sales maintenance of the chiller. Moreover, the maintenance cost of the chiller compressor is relatively high.
-
09/18/2020
Jingliang Electronics-Air Compressor Sensor Solution
——High-quality, cost-effective to provide customers with perfect sensor solutions Precision Electronics-MEAS (MSI) Sensor Co., Ltd. is a precision electronic engineering expert who masters the world's leading silicon micromachining MEMS technology.