KIMO Transmitter CP101-PN
People who bought this item also viewed
KIMO Transmitter CP101-PN
KIMO Transmitter CP218-BN
KIMO Transmitter TH110PND5
KIMO Transmitter TH110-POES
Trafag Transmitter 920.2378.938
Atlas Copco Transmitter 1089051504
VECTOR Transmitter SDC-H1T1-16-A3-LCD
GF SIGNET Conductivity Meter 3-2821
FLUKE Pressure Gauge 730G01CN 2.8K
CAHO Temperature Controller H491KRV2-G
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Festo Air Cylinder DGC-50-200-G-PPV-A
COSEL Power Supply MGFS15243R3-R
Recent related posts
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
08/06/2020
How to prevent cold bridge phenomenon in cold storage construction
In the cold storage, the so-called "cold bridge" is actually a bridge that transfers heat. In adjacent warehouses with different warehouse temperatures or between the inside and outside of the warehouse
-
06/14/2020
About the six advantages of the fresh air system and the four details that need attention
About the six advantages of the fresh air system and the four details that need attention With the continuous improvement of living standards, coupled with whether the haze weather is invading, the fresh air system is gradually becoming a necessary choic ﰸ2 䀀 ᅵ皥 䖒皦즠Ʋ娼ི 㲈Ʋ 䌁皦隆 ᮔDž༬皧婆ིЀ 呄ᠾ鹨់༹皧 ࠄ 00븹먱댁珵理뛐珵Љ 䕄ྦ 뤂ᐱ變뚜
-
06/14/2020
At Schneider Electric, we believe that obtaining energy and using digital technology are people ’s basic power
At Schneider Electric, we believe that obtaining energy and using digital technology are people ’s basic power. We empower everyone to maximize the use of energy and resources, and ensure that everyone can enjoy Life at any time and any place. Is On.
-
11/24/2023
How to Replace Computer Cooling Fan? Computer Fan Replacement with Figures and Detailed Steps
With the advancement of technology, computers have become an indispensable tool in people's lives. A faulty cooling fan will affect the normal operation of the computer and may even damage other hardware devices.
-
08/10/2020
Precautions for the use of refrigeration compressor overload protector
Overload protectors for compressors used in air conditioners generally use snap-on bimetallic protectors, consisting of a heating wire, a bimetallic sheet and two static contacts, which are connected in series in the compressor circuit.
-
03/07/2022
Why an Oil-Free Air Compressor Better?
With the improvement of the industry and people's living standards, the requirements for industrial products
-
07/10/2020
Hitachi compressor features:
Hitachi compressor features: 1. Whether Hitachi compressors use refrigerant R22 or the new chlorine-free refrigerants R134a, R404A, R507A and R407C, they can operate smoothly and reliably.
-
07/28/2020
Analysis of common failure causes of hermetic refrigeration compressors
. How to identify the 3 terminals on the casing of a hermetic compressor?<br></br> The resistance between running terminal (R), starting terminal (S), common terminal (C), RS is greater than the resistance between SC and RC. The resistance between RS is equal to the resistance between SC and the resistance between RC.
-
08/04/2020
The working principle and structure of common condenser
The condenser is one of the important equipment in the refrigeration system. It transfers the heat of the superheated vapor of the refrigerant to the surrounding air or water through the heat-releasing surface of the condenser