M-SYSTEM Transmitter KPE-1A-H
People who bought this item also viewed
M-SYSTEM Transmitter M5RS-3A-R
Atlas Copco Transmitter 1089057545
VECTOR Transmitter SDC-H1T1-24-A3-W2
Adli Transmitter 4008.184.001
Danfoss Transmitter 084Z8215
EXTECH Conductivity Meter EC500
NKS NAGANO KEIKI GV50-171
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
ZIPPY Power Supply HG2-6350P
YUKEN Vane Pump PV2R23-26-60-L-RHAR-41
COKERY Belt 615-5GT
Recent related posts
-
06/13/2020
Refrigeration compressor installation conditions and precautions
The selection of the installation site is ignored by the staff. Often the compressor will be found at random after it is purchased and used immediately after piping.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
05/04/2023
What is Vapour Compression Refrigeration System?
Vapour compression refrigeration system (VCRS) is the most common cooling system used in modern refrigeration technology.
-
08/15/2020
How to install large-scale cold storage refrigeration equipment
The cold storage is mainly used as a constant temperature storage air-conditioning equipment for food, dairy products, meat, aquatic products, etc. The cold storage is a kind of low-temperature cold storage and also a kind of refrigeration equipment.
-
05/12/2022
6 Considerations When Selecting PLC?
The operating functions of PLC include logic operation, timing and counting functions. The simple operating functions include data shift, comparison, etc
-
06/20/2020
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high
[Experience] What happens if the compressor suction pressure is too high and the discharge pressure is too high Compressor suction pressure is too high, discharge pressure is too high 1. Too much refrigerant. Too much refrigerant will cause the suction pressure and discharge pressure to be too high at the same time. This is because when too much refrigerant fills the reservoir, it will occupy a part of the condenser volume, reducing the heat dissipation area and causing the condenser Poor condensation. Discharge excess refrigerant from the low-pressure side.
-
06/13/2020
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass"
The principle, installation and use of the bypass valve of the heater of the cold dryer Composition and principle of "heater bypass" The energy regulation of the system is generally composed of the following ways: Compressor parallel-multi-stage contro 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ
-
06/13/2020
Rotor refrigeration compressor characteristics
Rotor refrigeration compressor characteristics The rotor compressor is composed of three parts: the motor, the mechanical part, and the housing part. It is mostly used in refrigerators, household air conditioners, and small refrigeration equipment. Gener 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔ
-
12/29/2021
Car AC Compressor Troubleshooting-- Best Suggestions
Using a straight edge and a feeler gauge to examine the flatness error between cylinder head, cylinder block, crankcase and bottom cover, which should not be more than 0.05mm, otherwise, you should grind it.
-
09/03/2020
Introduction of simple pressure vessel and fixed pressure vessel for air compressor gas storage tank
As the fourth most widely used energy source, compressed air is second only to traditional energy sources such as electric energy. As a necessary product for air compressors, compressed air is widely used in various fields of national production and life in my country.