Baldor VFD Frequency Converter ID15V403-WR
Type: VFD
Brand: Baldor
Type: VFD
Brand: Baldor
Type: VFD
Brand: Baldor
Panasonic Servo Motor MSM012P1A
Omron HMI NT20S-ST161-V3
HENGSTLER Encoder RI58-O/1800EK.42KH
Belimo Actuator SM24A
Puls Power Supply QS40.241
Delta PLC Host DVP24SV11S2
JSCC Speed Reducer 60GK180H
MITSUBISHI Spindle Amplifier MDSBSPJ2-110
Beckhoff Module EL4031
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
NAMCO Switch EA170-33100
Yaskawa Servo Motor SGMAS-08A2A2C-Y1
PMI Linear Guideway MSC7LMLLFCN
CHINT Switch DZ20Y-100/3300T 80A
SUNX Sensor SL-CH1
SMC Solenoid Valve SYJ3243-5LZ
TEZUO Switch AZX8108
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
06/14/2020
The automobile air-conditioning compressor is the heart of the automobile air-conditioning refrigeration system and plays the role of compressing and transporting refrigerant vapor.
09/13/2022
The actuator device is a combination of the actuator part and the control valve in automatic control system.
03/03/2023
Cylinder piston sealing ring is essential for the normal functions of the cylinder. The piston sealing ring prevents fluid from bypassing the piston
09/16/2022
The basic hydraulic system components include oil tank, hydraulic pump, control valve, oil cylinder, connecting pipe and relief valve.
07/27/2020
It is necessary to find a good air conditioner to be able to reassure people. Inverter air conditioners are really good and are loved by people. So when people use such air conditioners, they should also know the refrigeration pressure of inverter air conditioners. At the same time, we should know what the refrigerant of inverter air conditioner is, so that it can be more helpful to the use of air conditioner.
09/16/2020
Abstract: The application technical requirements of the oil-gas separation core used in air compressors, and the problems that occur during the use of the oil-gas separation core are analyzed, and the matters to be noted before installation.
11/12/2021
The components of industrial control system (ICS) can be roughly divided into two categories according to their location: control center equipment and remote site equipment.
05/14/2022
PLC I/O is the part of the PLC that connects the brain of the PLC, the CPU, to the outside world, the machines.
01/03/2024
Printers are familiar to everyone and are one of the essential office tools for work. From inkjet, dot matrix, laser, to the now popular 3D technology, printers have developed rapidly.