Delixi VFD Frequency Converter CDI-E180G022/P030T4
People who bought this item also viewed
VACON VFD NXL00095C5H1SSV0000
Lenze VFD Frequency Converter E82EV752K4C
Lenze Servo Drive EVS9326-EIV004
Mitsubishi HMI F940GOT-LWD-C
HENGSTLER Encoder RI58-D/512ED.32KB
SIEMENS Actuator GIB136.1E
Advantech PLC ADAM-5013
JSCC Reduction Drive 90YR120GV22
Beckhoff Terminal Box Module IP2320-B310
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
SHAKO Air Cylinder PC16B300
Baumer Sensor OADM 250U1101/S14C
SCHNEEBERGER Linear Guideway BMB20-G1V1
Recent related posts
-
12/05/2020
Selection of compressed air dew point meter
Air compressor dew point meter-suitable for compressed air and compressor post-processing drying equipment dew point meter, Michell products include a variety of online dew point meter and portable dew point meter, as well as dew point meter analysis system, fast response speed and good reliability.
-
05/18/2022
How to Measure Air Pressure in A Cylinder?
During use, the cylinder piston bank will deteriorate due to wearing, ablation, gumming, carbon deposition and other reasons.
-
08/09/2020
What are the differences between non-standard refrigerators and standard refrigerators
Non-standard refrigerator means that it is different from standard refrigerator. Let’s take a box-sealed refrigerator as an example. It is mainly composed of a compressor, an evaporator, a condenser,
-
01/06/2021
Ten reasons why central air conditioning is not cooling
Ten reasons why central air conditioning is not cooling Today, go to the user's home for after-sales with the after-sales master. It has been checked that the outlet and return vents of each indoor unit are normal. When opening the window of the outdoo 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ڤ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/04/2022
Stepper Motor: Working Principle, Operating Modes & Application
Stepper motor, also known as <strong>step motor</strong>, <strong>stepping motor</strong>, converts received electric pulse signal into angular displacement or linear displacement.
-
08/14/2020
How much do you know about water-cooled chillers A few steps let you know
What is the cooling method of the chiller? A water-cooled chiller is one of them. It has many names. Some people say it is a chiller or a chiller. No matter which type, it is the same machine.
-
08/20/2020
Installation and placement conditions of cooling tower of thermal shock tester
Let's learn about the installation and placement conditions of the cooling tower of the thermal shock tester with the editor of okmarts.com! 1. The ground is flat and well ventilated;
-
07/09/2020
Impact of COVID-19 on Global Gas Powered Air Compressors Market Outlook and Possibilities (2020-2029) || Hitachi, NorthStar, Rolair Systems
Study accurate information about the Gas Powered Air Compressors Market: Statistics, Facts and Figures, Growth Overview, Size, Major Players, Swot Analysis Industry Outlook and Regional Analysis, and Forecast To 2029. Extensive Study on Impact of the novel coronavirus (COVID-19) pandemic on the Gas Powered Air Compressors market originally based on Current Research of Potential Growth Challenges and Future Progress till 2029.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
07/22/2020
The ranking of compressor industry companies has changed so much
Due to the high technical threshold and high capital investment of the compressor industry, the concentration of the top five brands of the five major compressors in the industry has exceeded 63%, but the five major products also reflect different differentiation and evolution trends.<br></br>