Parker VFD Frequency Converter 10G-42-0030-BN
People who bought this item also viewed
Yolico VFD Frequency Converter YD3037-T4N
Fuji VFD Frequency Converter FRN7.5G11S-4EN
Mitsubishi Servo Motor HG-KN73J
Fuji VFD Frequency Converter FRN3.7C1S-4C
Rockwell AB Power Supply 80026-518-01-R
Siemens PLC 6ES7223-1HF22-0XA8
TSUNTIEN Speed Reducer TTRAD-25E
MITSUBISHI Spindle Amplifier MDS-D-SP2-8040
HONGFA Relay HF105F-1-048D-1HS
Bairuiou Battery BT12-40
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Recent related posts
-
06/14/2020
Air conditioning expansion valve
What is the principle of air conditioning expansion valve? The electronic expansion valve is a throttling element that can enter the refrigerant flow of the refrigeration device according to a preset procedure
-
06/14/2020
Super High Pressure Compressor
Super high pressure compressor proven to 700 bar using CO2 Concepts and Enhanced technologies
-
08/09/2023
Heat Pump Not Working in Cold Weather: Causes and Solutions
A heat pump is a popular heating and cooling system that works by transferring heat from one place to another. It can heat your home in the winter and cool it in the summer, making it a versatile and cost-effective option for many homeowners.
-
08/03/2020
The difference between refrigerant R404A and R507
Refrigerant is also called refrigeration working fluid, which is the blood of refrigeration system. It is called refrigerant, refrigerant or Freon in many places.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/15/2020
80 with display water level sensor, field display transmitter
80 with display water level sensor, field display transmitter Guangdong pressure sensor, Foshan pressure transmitter, Shunde pressure sensor PTH601S adopts diffused silicon piezoresistive core or ceramic piezoresistive core, 316 stainless steel structure, mainly suitable for liquid level measurement and control of rivers, underground water levels, reservoirs, water towers and containers.
-
09/06/2022
What is the Difference between Synchronous and Induction Motor
Electric motors are roughly divided into three types, synchronous motor, asynchronous motor
-
11/17/2021
Why Commercial Ice Maker not Work and Solutions
In modern city life, it's easy to see ice makers in restaurants, supermarkets, bars, cafes and other places, and there are car ice makers too.
-
04/18/2024
Mitsubishi Servo Drive Fault Codes and Troubleshooting Methods
Mitsubishi servo system consists of servo motor, controller, and servo drive (also called servo amplifier), mainly including MR-J2S series, MR-J series, MR-H series, MR-C series, MR-J2 series, MR-J2S series, MR-E series, MR-J3 series, MR-ES series, MR-JE series, MR-J4 series, etc.
-
06/18/2020
The main reason for the slow heating of air conditioners
The main reason for the slow heating of air conditioners There are several reasons for the slow heating of air conditioners: The dirt of the transpiration device and the condenser is too thick, which will cause air flow blockage, affect the heat declaration, and make the air conditioning heating a big discount. The filter is not cleaned for a long time<img src="{{media url="wysiwyg/The_main_reason_for_the_slow_heating_of_air_conditioners.jpg"}}" alt="" />