Voltage: three phase
Input: AC380-460V 50/60Hz
Output: 13A 3PH AC380-460Vmax
FREQ Range: 0.2-400Hz
Power supply capacity: 20KVA
Shihlin VFD Frequency Converter SH-040-11K
People who bought this item also viewed
Fuji VFD Frequency Converter FRN55G11S-4CX
Lenze VFD Frequency Converter E82EV552-4C200
Panasonic Servo Motor MHMD042S1T
Mitsubishi HMI GT2510-VTBA
Belimo Actuator NRQ24A
Schneider Processor module PLC BMEP582040H
SEND Speed Reducer SZG-35F-750-12.5
SAMSUNG RAM Card M471A1K43CB1-CTD
ABB IGBT Module FS225R12KE3/AGDR-71C
NEC Relay EE2-24TNUX
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
HONGFA Relay HF32F-005-HS3
TRIAD Transformer VPM100-25000
Carel Temperature Controller RCBHS1H0E1K
Balluff Sensor BUS003H
Recent related posts
-
01/04/2021
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor Piston Displacement, Compressor Capacity, Clearance Volume of Compressor Introduction This article describes some important terms related to the refrigeration and air 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
07/18/2020
Explanation of the excellent performance of each component of the screw chiller
The application of screw refrigeration compressors is becoming more and more common, and some of them have entered the period of frequent failures. When the abrasion of the female and male rotors, body, and exhaust end seat of the refrigeration compressor reaches above 0.65rnm, vibration will occur when the refrigeration compressor is running, the sound is abnormal, the cooling capacity is reduced, and the compressor cannot work normally.
-
08/19/2020
Application of large temperature difference cooling water system in industrial cooling system
In the industrial cooling system, in order to meet the process requirements, small flow materials need to be cooled with a large temperature difference (for example, a certain juice beverage needs to cool the material from 30°C to 5°C
-
08/17/2020
Analysis of 4 major reasons for the high energy consumption of building HVAC systems
1. Analysis of the high energy consumption of the building HVAC system The reasons for the high energy consumption of building HVAC systems are mainly reflected in the following aspects:
-
06/22/2020
Working principle of steam compressor_steam compressor application
Working principle of steam compressor_steam compressor application Working principle of steam compressor After the steam is filtered by the filter, clean steam then enters the host cavity through the intake valve, and the volume of the cavity changes from large to small to compress the steam. The volume of the cavity is changed by the rotor rotating under the drive of the motor. <img src="{{media url="Working_principle_of_steam_compressor_steam_compressor_application.jpg"}}" alt="" />
-
05/25/2022
How to Install The Safety Light Curtain?
In order to ensure the normal operation and the safety of operators, we must install the safety light curtain according to the correct methods and steps.
-
08/05/2020
Can you judge whether the refrigeration compressor is leaking in 5 steps
Insert the power plug of the air conditioner into the power source, and the air switch will trip immediately! Compressor leakage? Follow the following five steps to confirm the compressor leakage fault.
-
09/06/2020
Design steps of two-wire AC current transmitter
Known high-current current transformers convert different currents into 0~5A alternating current for on-site display. For long-distance transmission, the current must be converted into a standard DC current signal of 4-20mA before transmission.
-
07/17/2020
refrigerating system
4.1 Pressure vessels and pipelines are often contacted by refrigeration and air-conditioning technicians;; components of various systems; for example, placing an R--22 refrigerant storage tank on the rear panel of a car with a common barrier; The hot summer sun can make the temperature of the steel pipe reach 110F; the total area of
-
08/13/2020
Four types of safety protection measures for refrigeration compressors
As the most important component of the chiller, the motor for the refrigeration compressor plays an important role in the after-sales maintenance of the chiller. Moreover, the maintenance cost of the chiller compressor is relatively high.