Rotation CCW or CW
Mounting Flange SAE 2 Bolt B
Maximum Continuous†
Pressure 248 bar [3600 PSI]*
Maximum Intermittent†† Pressure 276 bar [4000 PSI]**
Minimum Speed at Continuous Pressure 750 RPM
Maximum Continuous Inlet Temperature 107°C [225°F]
Minimum Operating Temperature -29°C [-20°F]
Maximum Inlet Vacuum at 82°C [180°F] and Rated Speed 6.0 In. Hg
vickers Gear Pump GPA2-16-EK1-20-R
People who bought this item also viewed
Sumitomo Gear Pump QT61-200-A
Bellofram Proportional Valve 969-710-001
KOMPASS Check Valve MBB-03-B
KOMPASS Overflow Valve MPW-06-B
YUKEN Piston Pump A70-FR04E140A-6014
KCL Vane Pump VQ45-136-F-RAA-02
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
UNIVER Solenoid Valve AE-1010A
Keyence Sensor FS-N13CP
Autonics Sensor PRCM18-8AO
PANASONIC Capacitor 80V 10000UF
SMC Solenoid Valve VZ312-5GB-M5
Recent related posts
-
06/14/2020
Fresh air system allows you to breathe fresh air at home for 24 hours
Fresh air system allows you to breathe fresh air at home for 24 hours In recent years, poor outdoor air quality has caused sensitive people to induce respiratory diseases;
-
07/13/2020
Danfoss training-common faults and analysis of compressors
Danfoss training-scroll compressor I participated in Danfoss' service provider training and learning twice a week this week, mainly on scroll compressors (MLM series, MLZ series, LLZ series), and the recently hot scroll compressors for heat pumps (SH series, PSH series) ). And analyze the common faults of the compressor and exchange solutions.
-
01/13/2021
Condenser-overview
Condenser (Condenser), which is a part of the refrigeration system, is a type of heat exchanger. It can convert gas or vapor into liquid, and transfer the heat in the pipe to the air near the pipe in a fast way. The working process of the condenser is an 器2 䀀 ᅵ皥 䖒皦즠Ʋ奌ི 㲈Ʋ 䌁皦 ᮔDž༬皧奖ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧ؠ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ 識 理艏S杴 識杴 㥲ᐲ
-
09/07/2020
Reasons for rust or corrosion of gas tank
The gas storage tank is a part of the post-processing equipment of the air compressor, which mainly plays the role of gas storage, buffering, pressure reduction, and drainage. It will inevitably cause corrosion in the air, rain or humid atmosphere after long-term use or use for many years.
-
12/27/2021
Basics of Servo Motor You Should Know
Servo control refers to the effective control of the position, speed and acceleration of certain object to meet a certain purpose. It is one of the most important control methods in modern industry.
-
07/14/2020
Key factors for energy saving of screw air compressor
Key factors for energy saving of screw air compressor The rotor profile of the screw air compressor has a certain impact on energy saving. Before 2000, the screw air compressor was still in the growth period, and reliability was the main problem. At that time, the rotor profile development of screw air compressors made reliability the main goal.
-
06/14/2020
Refrigeration compressor configuration application and precautions
Compressor configuration Generally speaking, semi-hermetic compressors are equipped with: oil filter, oil hole, exhaust with pressure gauge interface, suction cut-off valve, suction filter, sight glass.
-
08/20/2020
Daily maintenance and maintenance methods of ground source heat pumps
At present, many office buildings and single-family villas have installed ground source heat pumps, but you should not think that you will have nothing to worry about after installation.
-
06/14/2020
What is the difference between heating 24 ℃ and cooling 24 ℃
Regardless of the room temperature, as long as the air conditioner is in the cooling mode and is in a working state, the wind blown out is cold wind. To put it bluntly, the temperature of the blown air is determined by the operation mode of the air condit 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦 ᮔDž༬皧煞क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥
-
09/07/2020
The difference between permanent magnet variable frequency air compressor and ordinary air compressor
With the development of science and technology, air compressors, as an important power equipment, are widely used in many industrial fields such as machinery, metallurgy, building materials, electronics and electricity, chemicals, food, and textiles.