There is no price at present, you can Request a Quote
Rated voltage: 3-380-480 V
Rated frequency: 50/60 Hz
Ziehl Abegg Fan FN063-ZIQ.DG.V7P2
There is no price at present, you can Request a Quote
People who bought this item also viewed
Sanyo Denki Fan 109P0412H731
Ebmpapst Fan R2E140-AQ03-12
Ziehl Abegg Fan FN050-VDK.4I.V7P1
Ziehl Abegg Fan RH25V-6IK.BA.1R
Ziehl Abegg Fan FN035-VDK.0F.V7P2
Ziehl Abegg Fan FN040-VDK.OF.V7P1
SUNON Fan MG60090V1-C060-S99
SUNON Fan KDE1204PFB2-8
Delta Fan THB1212B-A
SUNON Fan DP203A 2123LSL.GN
Tecumseh Compressor HGA0470EXA
COSEL Power Supply LFA150F-24-CR
TRIAD Transformer F20-1800
ABB Circuit Breaker SH204-B16
PARKER Filter G02865
Danfoss Sight Glass SGP16SN
FUJI IGBT Module 7MBP100VEA120-50
HONGFA Relay HFD3-V-24
MURATA Capacitor NFM3DPC223R1H3L
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
FOTEK Flowmeter KTP-15-PP-5M
SMC Solenoid Valve VP542-4DZ1-03A-F
SIEMENS Servo Motor 1FK7032-2AF21-1AA0
Banner Sensor SMW915FPQD
PIZZATO Switch FR 1007
Recent related posts
-
08/17/2020
Principle analysis and characteristics of new technology machines for central air conditioning
1. Water magnetization treatment technology Using the magnetic field effect to treat water is called magnetization treatment of water.
-
05/11/2022
Mitsubishi air conditioner E1, E2, E3, E4, E5, E6 and other faults, how to troubleshoot and repair?
Whether there is a fault in the indoor and outdoor units can be known by the access code of the remote control, the content of the green LED
-
10/25/2021
How to Use Rotary Encoder on Arduino Board UNO
In our last article, you may have learned how to connect a rotary encoder on Arduino development board UNO.
-
08/05/2020
Selection skills of precision air conditioner and comfort air conditioner
When doing intelligent and informatized projects, it is inevitable to do computer room projects. Air-conditioning is inevitable for computer room engineering. Some people will say that the cost of precision air-conditioning is so high.
-
01/04/2021
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor
Compression Ratio, Capacity and Volumetric Efficiency of the Refrigeration Compressor Piston Displacement, Compressor Capacity, Clearance Volume of Compressor Introduction This article describes some important terms related to the refrigeration and air 器2 䀀 ᅵ皥 䖒皦즠Ʋ㉄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㉎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵
-
08/16/2020
What is the structure of the fan coil
The fan coils we usually touch mainly include horizontal concealed fan coils, horizontal surface mounted fan coils, vertical surface mounted fan coils, vertical concealed fan coils, and other methods.
-
06/19/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
06/13/2020
11 common problems in refrigeration compressors, do you know these
11 common problems in refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
05/01/2023
Types of Compressors for Air Conditioning and Refrigeration Applications
The compressor is the core energy-consuming component of the refrigeration system, and the capacity and characteristics of the compressor determine the performance of the refrigeration system.
-
06/19/2020
Application advantages and working process analysis of air energy heat pump
Air energy heat pump is to use the energy in the air to generate heat energy. It can provide 24 hours a day with large water volume, high water pressure and constant temperature to provide the family with different hot water, cooling and heating needs, and at the same time can meet the above requirements with the least energy consumption.<img src="{{media url="Application_advantages_and_working_process_analysis_of_air_energy_heat_pump.jpg"}}" alt="" />