ADDA Fan AD0612LB-G70
Type: Fan
Brand: ADDA
Type: Fan
Brand: ADDA
Type: Fan
Brand: ADDA
Ebmpapst Fan R3G450-AG33-01
ADDA Fan AB06505HX12DB00
ADDA Fan AQ0824HB-A70GL
ADDA Fan AD1212MB-A70GL
ADDA Fan AD0924UB-F91GP
Servo Fan D1225C12BBZP
KAKU Fan KA1725HA1SAT
Delta Fan TFA0948AE
SUNON Fan KDE0504PFB3-8
Bristol Compressor H22G094GPD
COSEL Power Supply PBA1000F-48-UF1
Siemens Contactor 3RT2325-1AK60
ZHONGDA Electric Motor 5RK120A1-CF
Danfoss Sight Glass SGI 19S
EMERSON Controller Module 1C31194G02
TYCO Relay JWD-107-7
TOKIN Capacitor FMOV104ZF
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
YEESEN Vane Pump TCVP-F15-15-D
MINDMAN Air Cylinder MCJT-11-40-25
Maeda Flowmeter MKCT35-4TAR
09/30/2022
There are three types of <strong>servo motor control</strong> modes (<strong>servo motor control techniques</strong>)
12/15/2023
In the realm of technology, servers serve as the backbone of numerous industries, powering everything from websites to data centers.
07/28/2022
The pump body is installed and fixed on a special foot rest with screws, and the foot rest is fixed on the base plate of the machine and equipment with bolts.
06/20/2020
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
07/23/2020
The main reasons for the overheating of exhaust temperature are as follows: high return air temperature, large heating capacity of the motor, high compression ratio, high condensation pressure, and improper refrigerant selection.<br></br> <br></br>
08/16/2020
In fact, the use of a descaling agent for descaling is a common practice for the descaling work of the chiller. Therefore, the chiller can completely use the descaling agent for descaling. This is not a problem.
07/07/2020
The aging of air conditioners caused fires. The heat is coming. Are your home appliances overaged? The police reminded: As summer is approaching, we should pay attention to the service life, quality and installation environment of household appliances. The wires of many electrical appliances are mainly insulated by a layer of rubber on the outside.
08/04/2020
A few years ago, central air-conditioning and fresh air systems were only high-end home improvement options in some villa areas. Now they have become the decoration s* options for most families.
08/20/2020
In the hot and hot summer, the frequency of use of industrial chillers is the highest in a year, and summer is also the season when industrial chillers have the most frequent high temperature alarms.
07/01/2020
How to adjust the capacity of refrigeration compressor The capacity of the compressor is determined according to the maximum production of BOG in the storage tank. After the compressor is selected, its capacity is constant. If the amount of inhaled air is greater than the amount of BOG produced in the tank, the tank pressure will drop.