There is no price at present, you can Request a Quote
ASCO Solenoid Valve 8210G033 110V
There is no price at present, you can Request a Quote
People who bought this item also viewed
KOGANEI Solenoid Valve F15T3-PS
Honeywell Solenoid Valve VE4025C1002
Ingersoll Rand Solenoid Valve 39198551
Schneider Sensor XMLRM01G0T75
Siemens Contactor 3RT2015-1AP04-3MA0
ABB Electric Motor M2BAX71MB2
Eaton Vickers Vane Pump 20V-05A-1B22R
HYTEK Gear Pump HG2-125-01R-VPC
Donaldson Filter P822769
Danfoss Sight Glass SGR 014-0006
Hitachi Expansion Valve Coil EKVDC12V
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Omron Sensor E2C-JC4CH
THK Linear Guideway LRB2565
CHINT Fuse RS711B 125A
Rockwell Allen-Bradley AB VFD 20P21AD412RA0NNN
Recent related posts
-
01/06/2021
Advanced frequency conversion technology of Mitsubishi Electric central air conditioner
Advanced frequency conversion technology of Mitsubishi Electric central air conditioner Advanced-frequency-conversion-technology-of-mitsubishi-electric-central-air-conditioner Since 1952, Mitsubishi Electric has entered the field of semiconductor rese 器2 䀀 ᅵ皥 䖒皦즠Ʋ㎄ᰙ 㲈Ʋ 䌁皦 ᮔDž༬皧㎎ᰙЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱 ᅵ皥 ب 巠皱㙲皦忈皱 ੨皦柘皱 즠Ʋǜ 勁皦즠Ʋب ǜ V / 펔B䌁皦 ᮔDž '鱤džၜ먢䇨珵呈ᠾ뤂ᐱ ⿇⬿먲僧ᐱ㥲ᐲ�僬㣢ᐲ ᠾ 랖僧Ѭ 識 �僬㣢ᐲ 臆S㥲ᐲ ᬄğ
-
09/15/2020
82 lake water level sensor, river transmitter
82 lake water level sensor, river transmitter okmarts.com pressure sensor, okmarts.com pressure transmitter, okmarts.com pressure sensor PTH601 uses diffused silicon piezoresistive core or ceramic piezoresistive core, 316 stainless steel structure, mainly suitable for rivers, groundwater levels, reservoirs, water towers and containers, etc. liquid level measurement and control.
-
06/14/2020
It is so simple to change the oil in a half-sealed piston compressor, can you
It is so simple to change the oil in a half-sealed piston compressor, can you? The semi-hermetic piston compressor must pay attention to the condition of the freezing oil during the first 500 hours of operation
-
01/03/2021
The knowledge about the intake valve of the screw air compressor is here
The air compressor intake valve can also be said to be an intake control combination valve, which has functions such as intake control, loading and unloading control, capacity adjustment control,
-
01/30/2023
Characteristics of Smart Pressure Transmitters
With the rapid rise of fieldbus technology, the industrial process control system is gradually developing towards fieldbus control system (FCS) with two-way communication and smart instrument control, bring about the smart pressure transmitter.
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
01/05/2021
Real Gas Model for an Electric Swashplate Refrigeration Compressor
Real Gas Model for an Electric Swashplate Refrigeration Compressor Author links open overlay panelMohammadArqam1Dzung VietDao1AmirJahangiri2MarkMitchell2PeterWoodfield1 1 School of Engineering and Built Environment, Griffith University, Australia 2 U 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦
-
06/14/2020
An explosion in a building in Haikou caused 1 death and 10 injuries. The initial judgment was that the central air conditioner was leaking
An explosion in a building in Haikou caused 1 death and 10 injuries. The initial judgment was that the central air conditioner was leaking According to the news released by Haikou, after an on-site investigation by experts, it was preliminarily judged th 器2 䀀 ᅵ皥 䖒皦즠Ʋ嫜ི 㲈Ʋ 䌁皦 ᮔDž༬皧嫦ིЀ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁珵뛐珵Љ 䕄ྦ 뤂ᐱ뚜珵 ᴴᏩ呄ᠾ퍘ᒥ 鹨់ᩄ ꋔྦ 瑉浥 巠皱㙲皦抐皱 巠皱 ੨皦柘皱
-
07/20/2020
Six aspects of repair and maintenance of refrigeration compressors in cold storage
A. During the initial operation of the cold storage unit, carefully observe the oil return of the compressor and keep it clean. If you find that the oil level is not clean enough or if the oil level drops, you should add oil or replace it with new oil in time. This can avoid poor lubrication
-
06/14/2020
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal, whether the fuse has been blown due to starting overload