There is no price at present, you can Request a Quote
Assembly position / location: Any position
Subplate surface finishing to ISO 4401: Acceptable roughness index, Ra<=0,8 recommended Ra 0,4 - flatness ratio 0,01/100
MTTFd values according to EN ISO 13849: 150 years, for further details see technical table P007
Ambient temperature: Standard = -20 - 70celsius degree
Storage temperature range: Standard = -20 - 80celsius degree
ATOS Solenoid Valve DHA-0631/2/PA-GK 24DC
There is no price at present, you can Request a Quote
People who bought this item also viewed
KOGANEI Solenoid Valve 100E1-SR-28W
Daikin Solenoid Valve C-KSO-G03-3CA-20
AirTac Solenoid Valve 3V2-06-NC
Tecumseh Compressor AWA5535EGH
Danfoss Transmitter 060G3814
Siemens Transformer 4AM4396-0EG60-0FS1
IFM Sensor SI1003
Danfoss Solenoid Coil BN230CS
SMC Proportional Valve ITV2050-04F2L2
Siemens Contactor 3TC7814-0EB
DANFOSS Check Valve NRD12S
LEEMIN Filter HX-250-M67
PANASONIC Capacitor 100V 150UF
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PIZZATO Switch FM 252-M2R24
Yuken Safety Valve S-BG-03-L-30
Copeland Compressor ZR68KC-PFV-522
PARKER Filter 932470
SMC Solenoid Valve VQZ1120B-5GB1-M5
CHELIC Air Cylinder JGAD80*90-B
Dwyer Transmitter 626-10-GH-P1-E1-S1
Recent related posts
-
11/16/2022
What is an Axial Fan?
Axial fans, also called axial flow fans, are very versatile and produce airflow in the same direction as the axis of the fan blades.
-
08/19/2020
Installation and debugging of thermal expansion valve in refrigeration equipment
The correct installation of the thermal expansion valve will also affect the performance of the refrigeration device. Before installation, check whether the expansion valve is in good condition, especially the temperature sensing mechanism.
-
08/11/2020
Correct adjustment method of opening degree of thermal expansion valve
The expansion valve is one of the four major components of the refrigeration system. It is an important device for regulating and controlling the flow and pressure of the refrigerant entering the evaporator, and it is also the "boundary line" between the high and low pressure sides.
-
07/05/2020
Hitachi screw compressor failure case
Hitachi screw compressor failure case The author summarizes the case of Hitachi screw compressor maintenance and replacement bearings, and shares the data, please send it to a friend to collect and forward it for use
-
08/07/2020
Use and selection of water pumps for HVAC systems
1. Chilled water pump:<br></br> In the chilled water loop, a device that drives water to circulate. The end of the air-conditioned room (such as fan coil, air handling unit, etc.)
-
04/12/2024
Servo Motor Applications: a Complete Guide
Servo motors are widely used in various mechanical equipment. It has the characteristics of fast response, high precision and high reliability, and can achieve precise position control, speed control and force control.
-
06/14/2020
Top 10 common faults in maintenance and debugging of refrigeration systems
What is the effect of pressure and temperature on the refrigeration system Refrigeration system performance testing involves many aspects, of which pressure and temperature are two points that cannot be bypassed. Today we will take a look at the pressure 器2 䀀 ᅵ皥 䖒皦즠Ʋ煔क़ 㲈Ʋ 䌁皦
-
06/14/2020
Is there any difference between refrigeration compressor, air compressor and air pump
Air compressor ≠ refrigeration compressor. Refrigeration compressor: It is a driven fluid machinery that raises the bottom pressure vapor to high pressure vapor. There are many types, such as nitrogen making equipment, refrigerant machine, air compress 器2 䀀 ᅵ皥 䖒皦즠Ʋ焬क़ 㲈Ʋ 䌁皦 ᮔDž༬皧然क़Ѐ 呄ᠾ鹨់༹皧 ࠄ 00령ꐱ댁
-
08/09/2020
How to deal with the refrigerant leakage of precision air conditioner in computer room
As we all know, the power density of equipment in the computer room is high, so the volume heat is high. The computer room for exchange and data still needs to be continuously cooled by air-conditioning compressors to meet the environmental temperature requirements of communication equipment.
-
11/22/2021
Benefits of Rosemount Fieldbus Transmitter
It is reasonable to say that Rosemount fieldbus transmitter series can help customers reduce the overall cost of the system.