There is no price at present, you can Request a Quote
double solenoid, 3 positions, spring centered
Assembly position / location: Any position for all valves except for type - 70 and 77 (without springs) that must be installed with horizontal axis if operated by impulses
Subplate surface finishing: Roughness index Ra 0,4 - flatness ratio 0,01/100 (ISO 1101)
MTTFd values according to EN ISO 13849: 150 years, for further details see technical table P007 Ambient temperature: Standard = -30 - 70celsius degree
Storage temperature range: Standard = -30 - 80celsius degree
ATOS Solenoid Valve DHI-0713/MV-X-120/60AC
There is no price at present, you can Request a Quote
People who bought this item also viewed
KOGANEI Solenoid Valve HA040-4E1
CHELIC Solenoid Valve SR-5201
MAC Solenoid Valve 912B-PM-501CA
Danfoss Transmitter 060G1223
CHINT Transformer TSGC2-30
Banner Sensor R55CW2
Danfoss Expansion Valve 068Z3277
Amico Check Valve 480 DN50
CAT Piston Pump 6811K
SUNTEC Gear Pump AS67A 7466-4
EMERSON Sight Glass AMI-1SS2
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
PARKER Switch FMUT1KVMU14M
TTO Oil Seal TC 35*80*8
Schneider Sensor XS118B3NAM12
KOGANEI Air Cylinder BDADL6X5
UNIVER Solenoid Valve CM-9680NA
Recent related posts
-
08/20/2020
The difference between cross-flow cooling tower and counter-flow cooling tower
The so-called cross-flow cooling tower is a type of cooling tower that allows air to flow horizontally through the water spray filler, and the water dragon falls vertically from the top of the tower
-
05/20/2022
5 Common Faults and Solutions of Air Cylinders?
Cause 1: The guide sleeve, rod seal ring or piston rod are worn. Solution 1: Replace it. Improve lubrication. Use guide rails.
-
08/20/2020
How to extend the life of commercial central air conditioners
Nowadays, buyers of commercial central air conditioners are increasing day by day. Many people find that the service life of commercial central air conditioners is greatly reduced after purchasing.
-
02/27/2021
Some common faults and solutions of servo motors
The temperature of the motor is too high or the motor is faulty with smoke the reason: 1). Excessive load 2). Two-phase operation
-
08/20/2020
The main difference between air-cooled chillers and water-cooled chillers
First of all, it is necessary to find out which types of chillers are divided into: General manufacturers will produce two types of water-cooled and air-cooled chillers.
-
07/20/2020
Characteristic description of abnormal temperature of compressor
The condensing valve is a valve used to remove condensate and air from the system, and the potential heat loss is large. The thermal imaging camera can monitor the working condition of the condensing valve to determine the steam utilization efficiency and avoid energy waste and leakage accidents
-
04/01/2022
How to Make a Fan Blow Cold Air?
In summer, in some specific places, or some economically constrained families, people have no air conditioning but only fans. When it’s especially hot, some people find that the fan wind gets hotter and hotter, which can't cool at all.
-
09/21/2020
Air compressor --- monitoring in operation
The components of a piston air compressor that need to be cooled with water include cylinders, intercoolers, aftercoolers, and lubricating oil coolers.
-
11/03/2023
How to Test Your Radiator Fan: A Step-by-Step Guide
A properly functioning radiator fan is crucial for maintaining the optimal temperature of your vehicle's engine.
-
03/01/2023
The Structure and Basic Working Principle of Air Cylinder
Air cylinder is composed of cylinder barrel, end cap, piston, piston rod, and sealing ring.