Max. response frequency : 35kHz
Max. allowable revolution : 3000rpm
Starting torque : Max. 40gf.cm(max. 0.00392N.m)
Resolution : 256P/R
Rotating direction : CW
Control output : NPN open collector
Power supply : 5VDC +-5%(ripple P-P: max. 5%)
Connection type : Axial cable type
Protection structure : IP50 We can also provide the following models
E58H12-800-6-L-24
E58H12-12-6-N-24-CS
E58SS10-400-3-N-5
E58SS6-1200-3-T-5-CS
EP58HB8-720-3R-P-5
E58SC6-5-3-T-24-CR
E40S6-1024-2-L-24
E50S8-1-2-V-24-CR
E58SC10-240-3-L-24
E58SC6-600-4-T-24-C
E58SS10-800-4-V-24-CR
E40HB12-100-3-V-5-C
E58SC10-300-3-L-5-C
E58SS6-300-4-V-5
E40HB6-60-2-N-5
E40H10-23-2-T-24
E58H12-1500-6-L-5-CS
E40HB10-5-2-L-24
For more information,please contact us freely
Autonics Rotary Encoder EP58SC10-256-3F-N-5
People who bought this item also viewed
Autonics Rotary Encoder E50S8-3600-6-L-5
Autonics Rotary Encoder ENH-100-1-T-24
Renishaw Encoder RESA30USB075B
LS Mecapion Encoder S48-8-1024ZT
Mitsubishi Servo Motor HG-KN43J-S100
Mitsubishi Servo Drive MR-J2S-500A
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Allen Bradley Servo Drive 2098-DSD-075-SE
AirTAC Air Cylinder TCL16X60
Rockwell A-B HMI 2711P-T6M20A
Recent related posts
-
08/14/2020
Selection requirements for cold storage refrigerants
The nature of the refrigerant will directly affect the type, structure, size and operating characteristics of the refrigerator, as well as the form, equipment structure, and economic and technical performance of the refrigeration cycle.
-
02/27/2021
How to maintain the servo motor?
How to maintain the servo motor 1. Regularly check the encoder connection line of the servo motor and the power connector of the servo motor to confirm that the connection is firm;
-
09/06/2020
Application of Piston Rod Settlement Monitoring System in Reciprocating Compressor
1. Introduction A petrochemical plant imported a reciprocating compressor from abroad, the model is: B254-4118N3.3, 4 rows of symmetrical balanced type, the import and export parameters are: 135kPa (A)@14℃, 3.4MPa (A)@35℃, rotation speed: 425r/min, stroke: 240mm.
-
06/25/2020
[Experience] Constant temperature and humidity box refrigeration system
[Experience] Constant temperature and humidity box refrigeration system Constant temperature and humidity box refrigeration system: 1 Two single-stage refrigeration system cascade refrigeration cycle; 2 Cascade refrigeration cycle of two-stage compression system;
-
02/18/2024
Understanding and Resolving the Issue of Furnace Blowing Cold Air and Won't Shut off
Winters bring a sense of coziness as we rely on our furnaces to keep our homes warm and comfortable. However, discovering that your furnace is blowing cold air and refusing to shut off can be a cause for concern.
-
09/04/2020
Quality is the life of a factory, but why is the position of quality-oriented the most embarrassing
Many factories believe that quality is the life of the factory. The managers of the factory also attach great importance to quality, but they would rather invest more sales staff in sales to push products
-
08/05/2020
How to solve the common old problems in the operation of chillers
In the pharmaceutical, food, chemical and other industries, process water cooling is required. The chiller has become a must-choice equipment for many industries.
-
07/19/2020
Refrigerant filling operation method of centrifugal chiller
The centrifugal chiller refrigeration compressor after completing the work procedure of filling the frozen lubricating oil, the next step should be the refrigerant filling operation, the method of operation is: (1) using copper pipes or PVC (polyvinyl chloride) pipes One end is connected with the filling valve at the lower part of the evaporator, and the other end is connected with the top joint of the refrigerant storage tank to ensure good sealing.
-
10/22/2021
List of Problems and Solutions for Centrifugal Air Compressor
As a speed type air compressor, centrifugal compressor can generate air flow moving in radial direction.
-
08/09/2020
Rosemount 3144P temperature transmitter FF fieldbus manual!
power supply Rosemount temperature transmitter FOUNDAIION fieldbus uses standard fieldbus power supply. The operating voltage of the transmitter is 9 to 32Vdc with a maximum of 11 mA. The rated voltage at the transmitter end is 42.4V dc, Wiring diagram