Belimo Actuator NVK24A-3-RE
People who bought this item also viewed
Belimo Actuator SY3U230-MF-T
Belimo Actuator SY8U230-MF-T
Johnson Controls Actuator VA-7202-1001
Belimo Actuator SM230ASR
Johnson Controls Actuator M9116-ADA-1
Johnson Controls Actuator RA-3003-7227
AirTAC Air Cylinder ACQJ16X35-10S
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Copeland Compressor RS97C1E-CAV-101
SOG Oil Seal TC20*36*8
AirTAC Air Cylinder SULB50X150
Yaskawa Servo Motor UGJMED-40LA20F
CKD Air Cylinder SCPG2-L-00-6-70
Recent related posts
-
06/24/2020
What is the reason why the freezer is not cooling
It may be that the capillary is blocked and the refrigerant flow does not enter the evaporator. It may also be that the refrigerant needs to be replenished or the refrigeration system is leaking. If the buffer tube inside the compressor ruptures, there may be loose screws or it will cause no cooling. It is also possible that the expansion valve and the discharge valve are not adjusted properly, causing cold air to leak out. Need to check one by one, and then take the medicine.
-
07/16/2020
Three factors determine the quality of cold storage
The size of the cold storage should be designed according to the highest amount of agricultural products to be stored throughout the year. This capacity is calculated based on the volume that the stored products must occupy in the cold storage, plus the aisles between the rows, the space between the stack and the wall and ceiling, and the gap between the packaging.
-
06/14/2020
Cause Analysis of Refrigeration Compressor
Cause Analysis of Refrigeration Compressor Cannot Start or Stop Quickly After Start 1) First check the main circuit. Whether the power supply has power, whether the voltage is normal,
-
08/17/2020
How to adjust the refrigeration system of cold storage equipment to reduce operating costs
1. Reasonably adjust the operating parameters of the refrigeration system to improve equipment efficiency. The evaporating pressure and temperature of the refrigeration system and the condensing pressure and temperature are the main parameters.
-
06/14/2020
The difference between single and twin screw compressors is reflected in the following 6 aspects
The difference between single and twin screw compressors is reflected in the following 6 aspects
-
08/11/2020
Correct adjustment method of opening degree of thermal expansion valve
The expansion valve is one of the four major components of the refrigeration system. It is an important device for regulating and controlling the flow and pressure of the refrigerant entering the evaporator, and it is also the "boundary line" between the high and low pressure sides.
-
06/14/2020
Frequently asked questions about refrigeration compressors, do you know these
Frequently asked questions about refrigeration compressors, do you know these 1.Why control the impurity content and moisture content of the compressor and air conditioning system?
-
08/20/2020
Cold storage anti-corrosion and anti-frost coatings effectively solve the problem of frosting and corrosion
In the cold storage, when the dew point of the air is lowered by the cooling pipe surface, the moisture in the food and air will precipitate and condense on the pipe wall. If the pipe wall temperature is lower than 0°C, it will condense into a rain layer.
-
06/14/2020
The working principle of refrigeration compressors_The main performance parameters of refrigeration compressors
Working principle of refrigeration compressor
-
09/01/2020
The most complete version|Basic theoretical knowledge of compressed air (2)
Six, compression and compression ratio 1, compression Adiabatic compression is a compression process in which gas heat is not significantly transferred or transferred during the compression process.