There is no price at present, you can Request a Quote
Schneider Circuit Breaker OSMC32N3C32KG
There is no price at present, you can Request a Quote
People who bought this item also viewed
Schneider Circuit Breaker LV431940
Schneider Circuit Breaker A9V53240
Schneider Circuit Breaker LV432693
Siemens Circuit Breaker 3RV5041-4JA10
Fuji Circuit Breaker EW50EAG-3P032
Siemens Circuit Breaker 3RV1042-4KB10
TRIAD Transformer F-218X
HYUNDAI Contactor UMC185
Siemens Fuse 3NA3 817-2C
SANYOU Relay SFK-106DM
Schneider Resistor VZ3R010W270
Customers frequently viewed
IWAYA DENKI Water Pump 25CJT0752
Panasonic Servo Motor MHMF022L1V2M
Honeywell Solenoid Valve VE4025B1045
ROTEN Mechanical Seal 8E5K-22-X
SANDSUN Overload Pump VA08H-760
GS Battery 6-QW-60(450)-(55D23L-KR)
Rechi Compressor 44R273A
MINDMAN Air Cylinder MCQV2-11-40-200
Mitsubishi Compressor YB645WTG
Chigo Air Conditioner KFR-26GW-ABPK1+A3G
SLDR Tool for Metal Cutting M42-27.8mm
Recent related posts
-
07/02/2020
In the post-new crown era, what are the market opportunities for refrigeration companies
In the post-new crown era, what are the market opportunities for refrigeration companies When we thought that the fear and anxiety caused by the new crown epidemic were going away, when we set up stalls in full swing to prepare for the development of the night economy, the small-scale counterattack of the new epidemic in Beijing made the originally slightly relaxed nerves tense again.
-
07/09/2020
Global Centrifugal Compressor Market Market: Revenue Growth and Applications Insights
The Global Centrifugal Compressor Market Market Research Report 2020 published by Prophecy Market Insights is an all-inclusive business research study on the current state of the industry which analyzes innovative strategies for business growth and describes significant factors such as top developers/manufacturers
-
09/14/2020
What are the reasons for the high temperature of the air compressor
The air compressor is a transmission machine. If the equipment running at high speed is not properly lubricated or cooled, it will inevitably produce high temperature. Excessive temperature will cause changes in the physical coefficient values of the rotor and bearing materials, and in severe cases, the entire main engine will bite.
-
06/29/2020
Treatment of frost in crankcase when compressor head frost is serious
Treatment of frost in crankcase when compressor head frost is serious The frost on the cylinder head is caused by a large amount of wet steam or refrigerant sucked into the compressor. The main reasons for this situation are:
-
09/09/2020
What are the problems of traditional air compressors compared with frequency conversion air compressors
Variable-frequency air compressors have certain advantages in many aspects, so what are the problems of traditional air compressors compared to variable-frequency air compressors? Today I will tell you about the problems of traditional air compressors.
-
07/07/2020
What are the main faults of the compressor How to replace it if it is broken
Is the semi-closed screw compressor going up or down The views of these companies coincide In January and February, when the epidemic was the worst, many people in the industry worried whether this year's market would be "cold"!
-
03/15/2021
FANUC FANUC spindle drive fault diagnosis
The motor does not rotate or the speed is abnormal After starting the spindle drive system, if the main motor does not rotate or the speed is abnormal, the possible causes are as follows
-
06/20/2020
What are the causes of air conditioning trip
What are the causes of air conditioning trip 1. The contradiction between the rated current of the air conditioner and the current carrying capacity of the wire. Here are two formulas involved: ①The rated current of air conditioner I=P÷U ÷power factor, the power remains unchanged, the smaller the voltage, the greater the current required. ② The current carrying capacity of the wire I=U÷R, the voltage is proportional to the current. So when the power supply voltage is normal, we must consider the line voltage drop. The longer the line, the greater the resistance, the greater the voltage drop, and the smaller the output current at the end. However, because the power of the load remains unchanged, the voltage becomes smaller, and the current that needs to be output will be larger. At this time, the wire is forced to overload, and the time will cause heating, and eventually cause the tripping of the open circuit. Some friends said that the heat of the wire will not cause the tripping of the circuit breaker. In fact, the manufacturer of the air switch has made it clear in the relevant manuals that the heat of the wire will cause the air switch to trip. Because the wire heats up, the crimp terminal will also heat up, and the resistance will become larger and larger. The larger the resistance, the greater the current consumption, and the hotter it will be, a vicious cycle. 2. Leakage During the daily maintenance work, we will encounter the situation that the air circuit trips due to the leakage of electricity. At least I have not experienced it once or twice. Regardless of the leakage of the neutral line or the leakage of the live line, a long time will cause the circuit breaker to trip. Why does the electric leakage cause the MCB to trip? There are two situations. ① Good grounding. At the beginning, the leakage current was not large, and as time went by, the leakage current became larger and larger, and eventually evolved into a short circuit to ground, unable to close. ②There is no ground wire. If the equipment is not connected to the protective ground, when the wire leaks to the equipment, it is equivalent to adding a large shunt resistance. Like this problem, if the air conditioner does not have a ground wire, when the wire leaks to the air conditioner, the air conditioner is a very large shunt resistor and will consume a lot of current. Eventually, the wire will heat up or trip open. How to determine whether the trip caused by the above two aspects can be done with a clamp ammeter. ① Measure the voltage at the input and output to see if there is a significant change in voltage drop. ②Measure whether the output current exceeds the standard. So my suggestion is: first measure the supply voltage to see if it is within the allowable fluctuation range. Then measure the current to see if it exceeds the rated ampacity of the wire. Finally, check the data one by one according to the measured data to find out the reason.
-
09/09/2020
The relationship between air compressor power, pressure and volume flow
Air compressor terminology: What is the relationship between air compressor power, working pressure and volume flow? First, let's first understand the definition of the three.
-
06/24/2020
What is the problem with the poor cooling effect of the air conditioner
In the hot summer, I believe that many people can not do without air conditioning, air conditioning can allow us to spend this summer in a cool environment. However, in the process of using air conditioners, I believe that many people have encountered a situation where the cooling effect of the air conditioner is not good, so why is the cooling effect of the air conditioner not good? What needs to be solved.